The detrimental effects of a refractive-index mismatch on the image formation in a two-photon microscope were investigated. Point-spread functions (PSF's) were recorded with an oil-immersion objective numerical aperture (NA) of 1.3 and a water-immersion objective NA of 1.2 in an aqueous sample at different depths. For the oil-immersion objective the enlargement of the PSF volume with increasing depth yields an axial and a lateral loss in resolution of approximately 380% and 160%, respectively, at a 90-mu m depth in the sample. For the water-immersion objective no resolution decrease was found. Measurements on a thick aqueous biofilm sample shows the importance of matching the refractive index between immersion fluid and sample. With a good match, no loss in image resolution is observed. (C) 1999 Optical Society of America.
引用
收藏
页码:5995 / 6003
页数:9
相关论文
共 18 条
  • [1] A modified chemostat system to study the ecology of oral biofilms
    Bradshaw, DJ
    Marsh, PD
    Schilling, KM
    Cummins, D
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1996, 80 (02): : 124 - 130
  • [2] THE INFLUENCE OF SPECIMEN REFRACTIVE-INDEX, DETECTOR SIGNAL INTEGRATION, AND NONUNIFORM SCAN SPEED ON THE IMAGING PROPERTIES IN CONFOCAL MICROSCOPY
    CARLSSON, K
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1991, 163 : 167 - 178
  • [3] Multiphoton excitation provides optical sections from deeper within scattering specimens than confocal imaging
    Centonze, VE
    White, JG
    [J]. BIOPHYSICAL JOURNAL, 1998, 75 (04) : 2015 - 2024
  • [4] 2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY
    DENK, W
    STRICKLER, JH
    WEBB, WW
    [J]. SCIENCE, 1990, 248 (4951) : 73 - 76
  • [5] THE EFFECTS OF TOTAL INTERNAL-REFLECTION ON THE SPREAD FUNCTION ALONG THE AXIS IN CONFOCAL MICROSCOPY
    ENTWISTLE, A
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1995, 180 (02): : 148 - 157
  • [6] ABERRATIONS IN CONFOCAL FLUORESCENCE MICROSCOPY INDUCED BY MISMATCHES IN REFRACTIVE-INDEX
    HELL, S
    REINER, G
    CREMER, C
    STELZER, EHK
    [J]. JOURNAL OF MICROSCOPY, 1993, 169 : 391 - 405
  • [7] REFRACTIVE-INDEX-INDUCED ABERRATIONS IN 2-PHOTON CONFOCAL FLUORESCENCE MICROSCOPY
    JACOBSEN, H
    HANNINEN, P
    SOINI, E
    HELL, SW
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1994, 176 : 226 - 230
  • [8] Jacobsen H., 1995, Bioimaging, V3, P39, DOI 10.1002/1361-6374(199503)3:1<39::AID-BIO5>3.3.CO
  • [9] 2-Z
  • [10] Kano H., 1996, Bioimaging, V4, P187, DOI 10.1002/1361-6374(199609)4:3<187::AID-BIO9>3.3.CO