Purpose: To investigate a tetrahedral diffusion gradient encoding scheme to measure the diffusion tensor in vivo for human calf muscle. Materials and Methods: The theoretical TE which maximizes the signal-to-noise ratio (SNR) of the diffusion images was derived for both the orthogonal and tetrahedral sampling strategies and the SNR advantage verified experimentally. A diffusion echo-planar imaging (EPI) sequence was used to image five volunteers. Gradient cycling and geometric averaging was performed to eliminate cross-terms between the imaging and diffusion gradients. Results: Trace diffusion coefficients in human muscle are spatially invariant and have low intersubject variability (<4%). Images of the off-diagonal terms confirm the anisotropy of muscle, and fiber orientation maps were derived from these off-diagonal images, A noninvariant index of anisotropy, A(ratio) (average value: 1.28), was found to be less susceptible to noise than the invariant index. Conclusion: This technique is robust and can be readily implemented on clinical scanners with EPI capabilities.
引用
收藏
页码:87 / 95
页数:9
相关论文
共 19 条
[1]  
Armitage PA, 2000, MAGNET RESON MED, V44, P117, DOI 10.1002/1522-2594(200007)44:1<117::AID-MRM17>3.0.CO
[2]  
2-D
[3]   Inferring microstructural features and the physiological state of tissues from diffusion-weighted images [J].
Basser, PJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :333-344
[4]   A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging [J].
Bastin, ME ;
Armitage, PA ;
Marshall, I .
MAGNETIC RESONANCE IMAGING, 1998, 16 (07) :773-785
[5]   NUCLEAR MAGNETIC-RESONANCE MEASUREMENT OF SKELETAL-MUSCLE - ANISOTROPY OF DIFFUSION-COEFFICIENT OF INTRACELLULAR WATER [J].
CLEVELAND, GG ;
CHANG, DC ;
HAZLEWOOD, CF ;
RORSCHACH, HE .
BIOPHYSICAL JOURNAL, 1976, 16 (09) :1043-1053
[6]   Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results [J].
Conturo, TE ;
McKinstry, RC ;
Akbudak, E ;
Robinson, BH .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :399-412
[7]   Diffusion MRI: Precision, accuracy and flow effects [J].
Conturo, TE ;
McKinstry, RC ;
Aronovitz, JA ;
Neil, JJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :307-332
[8]   MRI CHARACTERIZATION OF DIFFUSION-COEFFICIENTS IN A RAT SPINAL-CORD INJURY MODEL [J].
FORD, JC ;
HACKNEY, DB ;
ALSOP, DC ;
JARA, H ;
JOSEPH, PM ;
HAND, CM ;
BLACK, P .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :488-494
[9]   TEMPERATURE MAPPING WITH MR IMAGING OF MOLECULAR-DIFFUSION - APPLICATION TO HYPERTHERMIA [J].
LEBIHAN, D ;
DELANNOY, J ;
LEVIN, RL .
RADIOLOGY, 1989, 171 (03) :853-857
[10]   The b matrix in diffusion tensor echo-planar imaging [J].
Mattiello, J ;
Basser, PJ ;
LeBihan, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :292-300