Characterization of an Nb/Al/AlOx/Al/Nb superconducting tunnel junction detector with a very high spatial resolution in the soft X-ray range

被引:15
作者
Bechstein, S [1 ]
Beckhoff, B [1 ]
Fliegauf, R [1 ]
Weser, J [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
superconducting tunnel junction (STJ); monochromatized undulator radiation; beam collimation; X-ray fluorescense (XRF) analysis; detector characterization; energy resolution; spatial resolution;
D O I
10.1016/j.sab.2003.12.011
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A cryogenic superconducting tunnel junction (STJ) detector device was characterized and evaluated. It consists of an Nb/Al/ AlOx/Al/Nb layered structure and contains four STJs with sizes between 70X70 mum(2) and 200X200 mum(2). For dedicated characterization experiments we employed monochromatized undulator radiation of high spectral purity, which is available at the PTB Radiometry laboratory at the electron storage ring BESSY II. We investigated the STJ energy resolution at various photon energies below 1500 eV with respect to the detector area, the illuminated area, the incident photon energy and the count rate while recording the detector response. Applying a 50 mum-aperture to collimate the incident beam, we achieved an energy resolution of less than 10 eV at a photon energy of up to 900 eV for the 141 X 141 mum(2)-sized STJ. When a 5 mum-pinhole was employed approximately 25 mm in front of the STJ for the beam collimation, the energy resolution was independent of the detector size-between 5 and 9 eV for energies between 0.3 and 1.5 keV. Furthermore, we scanned both the effective detector area and the adjacent regions with a beam defined by a 5 mum-pinhole offering a beam width smaller than 18 mum. In this scan, both the energy resolution and the pulse height scale changed strongly within the central area of the STJ. These effects and those originating from the leads and edges are discussed. In addition, these findings contribute to understanding the decreasing energy resolution for increasing effective detector areas. We expect that such spatially resolved measurements will prove to be a proper method for detector evaluation and contribute to improving the detector layouts. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 17 条
[1]   Investigation of high-resolution superconducting tunnel junction detectors for low-energy X-ray fluorescence analysis [J].
Beckhoff, B ;
Fliegauf, R ;
Ulm, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (04) :615-626
[2]   Cryogenic imaging spectrometers for X-ray astronomy [J].
de Korte, PAJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) :163-169
[3]   Energy resolution and high count rate performance of superconducting tunnel junction x-ray spectrometers [J].
Frank, M ;
Hiller, LJ ;
le Grand, JB ;
Mears, CA ;
Labov, SE ;
Lindeman, MA ;
Netel, H ;
Chow, D ;
Barfknecht, AT .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (01) :25-31
[4]  
Frank M, 2003, J X-RAY SCI TECHNOL, V11, P83
[5]   Detection of multiple fluorescent labels using superconducting tunnel junction detectors [J].
Fraser, GW ;
Heslop-Harrison, JS ;
Schwarzacher, T ;
Holland, AD ;
Verhoeve, P ;
Peacock, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (09) :4140-4144
[6]   High-resolution tunnel junction extreme ultraviolet detectors limited by quasiparticle counting statistics [J].
Friedrich, S ;
le Grand, JB ;
Hiller, LJ ;
Kipp, J ;
Frank, M ;
Labov, SE ;
Cramer, SP ;
Barfknecht, AT .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) :3330-3333
[7]   A superconducting detector endstation for high-resolution energy-dispersive SR-XRF [J].
Friedrich, S ;
Niedermayr, T ;
Drury, O ;
Cunningham, MF ;
van den Berg, ML ;
Ullom, JN ;
Loshak, A ;
Funk, T ;
Cramer, SP ;
Batteux, JD ;
See, E ;
Frank, M ;
Labov, SE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :1117-1120
[8]   Single photon imaging x-ray spectrometers using low noise current preamplifiers with dc voltage bias [J].
Friedrich, S ;
Segall, K ;
Gaidis, MC ;
Wilson, CM ;
Prober, DE ;
Kindlmann, PJ ;
Szymkowiak, AE ;
Moseley, SH .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) :3383-3386
[9]  
HUBER M, 2003, IN PRESS NUCL INSTRU
[10]   Barriers to quantitative electron probe x-ray microanalysis for low voltage scanning electron microscopy [J].
Newbury, DE .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2002, 107 (06) :605-619