Assessing mineral density in small trephined jawbone biopsy specimens

被引:8
作者
Denissen, H
Eijsink-Smeets, R
van Lingen, A
van Waas, R
机构
[1] Acad Ctr Dent Amsterdam, Dept Oral Funct & Implantol, NL-1066 EA Amsterdam, Netherlands
[2] Free Univ Amsterdam Hosp, Dept Nucl Med, Amsterdam, Netherlands
关键词
jawbone density; trephined biopsy specimens;
D O I
10.1034/j.1600-0501.1999.100408.x
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
This study reports the test of the hypothesis that mineral density can be precisely assessed in small trephined jawbone biopsy specimens. Mineral density was measured by dual-energy X-ray absorptiometry (DEXA) and peripheral quantitative computed tomography (pQCT). Ten fresh and ten histologically processed specimens, which were not the same, were measured. The coefficient of variations (CVs) for the alcohol stored and the histologic specimens by DEXA were respectively 1.60 and 1.71%. The CVs by pQCT for the total bone density in the alcohol stored and the histologic specimens were respectively 0.07 and 0.16%, for the trabecular bone density 0.69 and 1.04% and for the cortical bone density 0.07 and 0.12%. It was concluded that DEXA and pQCT are precise for mineral density assessment of small trephined jawbone biopsy specimens both alcohol stored and histologically processed.
引用
收藏
页码:320 / 325
页数:6
相关论文
共 13 条
[1]
CAMERON JR, 1986, J INVESTIGATIVE RADI, V3, P141
[2]
MEASUREMENT OF MANDIBULAR BONE-DENSITY EXVIVO AND INVIVO BY DUAL-ENERGY X-RAY ABSORPTIOMETRY [J].
CORTEN, FGA ;
VANTHOF, MA ;
BUIJS, WCAM ;
HOPPENBROUWERS, P ;
KALK, W ;
CORSTENS, FHM .
ARCHIVES OF ORAL BIOLOGY, 1993, 38 (03) :215-219
[3]
X-RAY DUAL-PHOTON ABSORPTIOMETRY - A NEW METHOD FOR THE MEASUREMENT OF BONE-DENSITY [J].
CULLUM, ID ;
ELL, PJ ;
RYDER, JP .
BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (739) :587-592
[4]
CERAMIC HYDROXYAPATITE IMPLANTS FOR THE RELEASE OF BISPHOSPHONATE [J].
DENISSEN, H ;
VANBEEK, E ;
LOWIK, C ;
PAPAPOULOS, S ;
VANDENHOOFF, A .
BONE AND MINERAL, 1994, 25 (02) :123-134
[5]
Denissen H, 1996, J BONE MINER RES, V11, P638
[6]
LONG-TERM REPRODUCIBILITY OF QUANTITATIVE COMPUTED-TOMOGRAPHY VERTEBRAL MINERAL MEASUREMENTS [J].
GRAVES, VB ;
WIMMER, R .
CT-JOURNAL OF COMPUTED TOMOGRAPHY, 1985, 9 (01) :73-76
[7]
THE EXCESSIVE LOSS OF BRANEMARK FIXTURES IN TYPE-IV BONE - A 5-YEAR ANALYSIS [J].
JAFFIN, RA ;
BERMAN, CL .
JOURNAL OF PERIODONTOLOGY, 1991, 62 (01) :2-4
[8]
KLEMETTI E, 1993, SCAND J DENT RES, V101, P219
[9]
The application of three-dimensional quantitative computed tomography to the maxillofacial skeleton [J].
Maki, K ;
Okano, T ;
Morohashi, T ;
Yamada, S ;
Shibaski, Y .
DENTOMAXILLOFACIAL RADIOLOGY, 1997, 26 (01) :39-44
[10]
COMPARATIVE X-RAY DENSITOMETRY OF BONES FROM OVARIECTOMIZED RATS [J].
SATO, M .
BONE, 1995, 17 (04) :S157-S162