Chest imaging with flat-panel detector at low and standard doses:: comparison with storage phosphor technology in normal patients

被引:32
作者
Herrmann, KA
Bonél, H
Stäbler, A
Kulinna, C
Glaser, C
Holzknecht, N
Geiger, B
Schätzl, M
Reiser, MF
机构
[1] Univ Munich, Inst Clin Radiol, D-81377 Munich, Germany
[2] Siemens Med Syst Inc, Erlangen, Germany
关键词
digital radiography; storage-phosphor radiography; flat-panel detector radiography; comparative studies; thorax anatomy;
D O I
10.1007/s00330-001-1166-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the performance of standard-dose and low-dose cesium iodide (CsI)-doted amorphous silicon (a-Si) flat-panel detector technology (FDT) as compared with storage-phosphor technology (SPT) in the depiction of relevant anatomical structures in chest radiography. In 75 patients referred for thoracic CT, digital chest radiographs were randomly obtained with either SPT at a standard dose (speed class S400, n=15). standard-dose FDT (S400. n=25) or FDT at a low dose (S800, n=25). Five radiologists evaluated the visibility of eight pulmonary and mediastinal anatomical structures using a five-point rating scale. To determine statistically significant differences between the three groups, the Mann-Whitney U-test was employed. No statistically significant differences were found in the depiction of eight criteria between SPT and standard-dose or low-dose FDT chest radiographs. The performance of FDT S400 was equal to SPT for most criteria and better for retrocardiac structures and soft tissue. FDT S800 was inferior to both SPT and FDT S400. Standard-dose FDT is equivalent to SPT in the depiction of relevant anatomical structures of the chest. Our results also indicate that a dose reduction of 50% with FDT may result in small but not significant decrease of image quality.
引用
收藏
页码:385 / 390
页数:6
相关论文
共 21 条
[1]   Principles of digital radiography with large-area, electronically readable detectors: A review of the basics [J].
Chotas, HG ;
Dobbins, JT ;
Ravin, CE .
RADIOLOGY, 1999, 210 (03) :595-599
[2]   THRESHOLD PERCEPTION PERFORMANCE WITH COMPUTED AND SCREEN-FILM RADIOGRAPHY - IMPLICATIONS FOR CHEST RADIOGRAPHY [J].
DOBBINS, JT ;
RICE, JJ ;
BEAM, CA ;
RAVIN, CE .
RADIOLOGY, 1992, 183 (01) :179-187
[3]   DETECTION OF PNEUMOTHORAX - COMPARISON OF DIGITAL AND CONVENTIONAL CHEST IMAGING [J].
FAJARDO, LL ;
HILLMAN, BJ ;
POND, GD ;
CARMODY, RF ;
JOHNSON, JE ;
FERRELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :475-480
[4]   SELENIUM-BASED DIGITAL RADIOGRAPHY OF THE CHEST - RADIOLOGISTS PREFERENCE COMPARED WITH FILM-SCREEN RADIOGRAPHS [J].
FLOYD, CE ;
BAKER, JA ;
CHOTAS, HG ;
DELONG, DM ;
RAVIN, CE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) :1353-1358
[5]   Digital radiography versus conventional radiography in chest imaging:: Diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study [J].
Garmer, M ;
Hennigs, SP ;
Jäger, HJ ;
Schrick, F ;
van de Loo, T ;
Jacobs, A ;
Hanusch, A ;
Christmann, A ;
Mathias, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (01) :75-80
[6]   DIGITAL CHEST IMAGING WITH A SELENIUM DETECTOR - COMPARISON WITH CONVENTIONAL RADIOGRAPHY FOR VISUALIZATION OF SPECIFIC ANATOMIC REGIONS OF THE CHEST [J].
HEESEWIJK, HPM ;
NEITZEL, U ;
VANDERGRAAF, Y ;
DEVALOIS, JC ;
FELDBERG, MAM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) :535-540
[7]   EFFECTS OF REDUCED EXPOSURE ON COMPUTED RADIOGRAPHY - COMPARISON OF NODULE DETECTION ACCURACY WITH CONVENTIONAL AND ASYMMETRIC SCREEN-FILM RADIOGRAPHS OF A CHEST PHANTOM [J].
KIMMESMITH, C ;
ABERLE, DR ;
SAYRE, JW ;
HART, EM ;
GREAVES, SM ;
BROWN, K ;
YOUNG, DA ;
DESERAN, MD ;
JOHNSON, T ;
JOHNSON, SL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :269-273
[8]   DIGITAL RADIOGRAPHY OF SUBTLE PULMONARY ABNORMALITIES - AN ROC STUDY OF THE EFFECT OF PIXEL SIZE ON OBSERVER PERFORMANCE [J].
MACMAHON, H ;
VYBORNY, CJ ;
METZ, CE ;
DOI, K ;
SABETI, V ;
SOLOMON, SL .
RADIOLOGY, 1986, 158 (01) :21-26
[9]   PORTABLE CHEST IMAGING - COMPARISON OF STORAGE PHOSPHOR DIGITAL, ASYMMETRIC SCREEN-FILM, AND CONVENTIONAL SCREEN-FILM SYSTEMS [J].
NIKLASON, LT ;
CHAN, HP ;
CASCADE, PN ;
CHANG, CL ;
CHEE, PW ;
MATHEWS, JF .
RADIOLOGY, 1993, 186 (02) :387-393
[10]   MEDIASTINAL ABNORMALITIES - DETECTION WITH STORAGE PHOSPHOR DIGITAL RADIOGRAPHY [J].
SCHAEFER, CM ;
GREENE, R ;
HALL, DA ;
LINDEMANN, SR ;
LLEWELLYN, HJ ;
MCCARTHY, KA ;
PILESPELLMAN, ER ;
RUBENS, JR .
RADIOLOGY, 1991, 178 (01) :169-173