Principles of digital radiography with large-area, electronically readable detectors: A review of the basics

被引:127
作者
Chotas, HG
Dobbins, JT
Ravin, CE
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Digital Imaging Res Div, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Biomed Engn, Durham, NC 27710 USA
关键词
radiography; digital; direction conversion; indirect conversion; selenium detector; technology;
D O I
10.1148/radiology.210.3.r99mr15595
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Electronically readable, large-area x-ray detectors that promise rapid access to the image for diagnosis, improved image quality relative to that of screen-film and storage phosphor-based radiography, reduced patient examination time, a reduction of consumable agents, and possibilities for reduced patient exposure will soon be commercially available for digital radiography.
引用
收藏
页码:595 / 599
页数:5
相关论文
共 21 条
  • [1] XERORADIOGRAPHY
    BOAG, JW
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (01) : 3 - 37
  • [2] BUNCH PC, 1992, P SOC PHOTO-OPT INS, V1653, P46, DOI 10.1117/12.59484
  • [3] Amorphous silicon x-ray image sensor
    Chabbal, J
    Chaussat, C
    Ducourant, T
    Fritsch, L
    Michailos, J
    Spinnler, V
    Vieux, G
    Arques, M
    Hahm, G
    Hoheisel, M
    Horbaschek, H
    Schulz, R
    Spahn, M
    [J]. PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 499 - 510
  • [4] Memory artifact related to selenium-based digital radiography systems
    Chotas, HG
    Floyd, CE
    Ravin, CE
    [J]. RADIOLOGY, 1997, 203 (03) : 881 - 883
  • [5] EFFECTS OF UNDERSAMPLING ON THE PROPER INTERPRETATION OF MODULATION TRANSFER-FUNCTION, NOISE POWER SPECTRA, AND NOISE EQUIVALENT QUANTA OF DIGITAL IMAGING-SYSTEMS
    DOBBINS, JT
    [J]. MEDICAL PHYSICS, 1995, 22 (02) : 171 - 181
  • [6] DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES
    DOBBINS, JT
    ERGUN, DL
    RUTZ, L
    HINSHAW, DA
    BLUME, H
    CLARK, DC
    [J]. MEDICAL PHYSICS, 1995, 22 (10) : 1581 - 1593
  • [7] X-RAY-IMAGING WITH AMORPHOUS SELENIUM - DETECTIVE QUANTUM EFFICIENCY OF PHOTOCONDUCTIVE RECEPTORS FOR DIGITAL MAMMOGRAPHY
    FAHRIG, R
    ROWLANDS, JA
    YAFFE, MJ
    [J]. MEDICAL PHYSICS, 1995, 22 (02) : 153 - 160
  • [8] SELENIUM-BASED DIGITAL RADIOGRAPHY OF THE CHEST - RADIOLOGISTS PREFERENCE COMPARED WITH FILM-SCREEN RADIOGRAPHS
    FLOYD, CE
    BAKER, JA
    CHOTAS, HG
    DELONG, DM
    RAVIN, CE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) : 1353 - 1358
  • [9] X-RAY-INDUCED HOLE TRAPPING IN ELECTRORADIOGRAPHIC PLATES
    KASAP, SO
    AIYAH, V
    BAILLIE, A
    LEIGA, AG
    [J]. JOURNAL OF APPLIED PHYSICS, 1991, 69 (10) : 7087 - 7096
  • [10] IMAGE QUALITY OF A DIGITAL CHEST RADIOGRAPHY SYSTEM BASED ON A SELENIUM DETECTOR
    NEITZEL, U
    MAACK, I
    GUNTHERKOHFAHL, S
    [J]. MEDICAL PHYSICS, 1994, 21 (04) : 509 - 516