Statistical evaluation of an analytical GC/MS method for the determination of long chain fatty acids

被引:17
作者
Campo, P
Sorial, GA
Suidan, MT
Venosa, AD
机构
[1] Univ Cincinnati, Dept Civil & Environm Engn, Cincinnati, OH 45221 USA
[2] US EPA, Natl Risk Management Res Lab, Cincinnati, OH 45268 USA
关键词
long chain fatty acids; calibration; linearity; detection limit;
D O I
10.1016/j.talanta.2005.06.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In-depth evaluation of an analytical method to detect and quantify long chain fatty acids (C-8-C-16) at trace level concentrations (25-1000 mu g/l) is presented. The method requires derivatization of the acids with methanolic boron trifluoride, separation, and detection by gas chromatography-mass spectrometry. The calibration experiments passed all the tested performance criteria such as linearity, homoscedasticity, and ruggedness. The detection limits and related quantities were computed by applying the method detection limit, and the calibration line approximation. The values obtained by applying the latter approach were more reliable and consistent with the actual statistical theory of detection decisions and yielded the following concentrations: C-8, 87.6 mu g/l; C-10, 45.2 mu g/l; C-11, 39.9 mu g/l; C-12, 37.7 mu g/l; C-14, 41.4 mu g/l and C-16, 40.6 mu g/l. Two different gas-liquid chromatographic columns were tested and similar results achieved, which shows the ruggedness of the method. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:888 / 894
页数:7
相关论文
共 40 条
[1]  
AGREN JJ, 1992, J LIPID RES, V33, P1871
[2]   RELIABLE MEASUREMENT OF NON-ESTERIFIED LONG-CHAIN FATTY-ACID PATTERN IN BLOOD-PLASMA [J].
BORRA, C ;
COSMI, G ;
DICORCIA, A ;
SAMPERI, R .
JOURNAL OF CHROMATOGRAPHY, 1984, 311 (01) :9-15
[3]  
CALABRESE KL, 1987, J CHROMATOGR, V386, P199
[4]   Estimate of gas chromatographic blanks - Application to detection limits evaluation as recommended by IUPAC [J].
Casado, AG ;
Rodriguez, LC ;
Hernandez, EA ;
Vilchez, JL .
JOURNAL OF CHROMATOGRAPHY A, 1996, 726 (1-2) :133-139
[5]  
Casado AG, 1998, WATER RES, V32, P3168
[6]   Initial evaluation of quantitative performance of chromatographic methods using replicates at multiple concentrations [J].
Castillo, MA ;
Castells, RC .
JOURNAL OF CHROMATOGRAPHY A, 2001, 921 (02) :121-133
[7]  
Chappe P., 1994, Revue des Sciences de l'Eau, V7, P395
[8]   Ensuring both normality and homocedasticity of chromatographic data-ratios for internal-standard least-squares calibration [J].
Cuadros-Rodriguez, L ;
Gonzalez-Casado, A ;
Garcia-Campana, AM ;
Vilchez, JL .
CHROMATOGRAPHIA, 1998, 47 (9-10) :550-556
[9]   NOMENCLATURE FOR THE PRESENTATION OF RESULTS OF CHEMICAL-ANALYSIS [J].
CURRIE, LA ;
SVEHLA, G .
PURE AND APPLIED CHEMISTRY, 1994, 66 (03) :595-608
[10]   Nomenclature in evaluation of analytical methods including detection and quantification capabilities (IUPAC Recommendations 1995) [J].
Currie, LA .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :105-126