Simultaneous recording of epileptiform discharges by MEG and subdural electrodes in temporal lobe epilepsy

被引:133
作者
Mikuni, N
Nagamine, T
Ikeda, A
Terada, K
Taki, W
Kimura, J
Kikuchi, H
Shibasaki, H
机构
[1] KYOTO UNIV,SCH MED,DEPT BRAIN PATHOPHYSIOL,SAKYO KU,KYOTO 60601,JAPAN
[2] KYOTO UNIV,SCH MED,DEPT NEUROSURG,SAKYO KU,KYOTO 60601,JAPAN
[3] KYOTO UNIV,SCH MED,DEPT NEUROL,SAKYO KU,KYOTO 60601,JAPAN
关键词
D O I
10.1006/nimg.1997.0272
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Spontaneous epileptiform discharges were recorded by whole head magnetoencephalography (MEG) and subdural electrodes simultaneously from two patients with medically intractable temporal lobe epilepsy, In one patient whose epileptiform discharges emerged from the lateral temporal lobe, simultaneously recorded MEG could estimate equivalent current dipole reliably near the tumor. The amplitude of the dipole was in proportion not only to the amplitude of epileptiform discharge but also to the number of subdural electrodes involved, In the other patient, MEG detected only a small proportion of epileptiform discharges, even when they were recorded by subdural electrodes from the mesial temporal lobe, It is concluded that the amplitude and the depth of epileptiform discharges would largely affect the sensitivity of dipole localization by MEG. (C) 1997 Academic Press.
引用
收藏
页码:298 / 306
页数:9
相关论文
共 29 条
  • [1] AHONEN AI, 1933, PHYSICA SCRIPTA T, V40, P198
  • [2] LOCALIZATION OF IMPLANTED DIPOLES BY MAGNETOENCEPHALOGRAPHY
    BALISH, M
    SATO, S
    CONNAUGHTON, P
    KUFTA, C
    [J]. NEUROLOGY, 1991, 41 (07) : 1072 - 1076
  • [3] MAGNETIC LOCALIZATION OF A DIPOLAR CURRENT SOURCE IMPLANTED IN A SPHERE AND A HUMAN CRANIUM
    BARTH, DS
    SUTHERLING, W
    BROFFMAN, J
    BEATTY, J
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1986, 63 (03): : 260 - 273
  • [4] DEMONSTRATION OF USEFUL DIFFERENCES BETWEEN MAGNETOENCEPHALOGRAM AND ELECTROENCEPHALOGRAM
    COHEN, D
    CUFFIN, BN
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1983, 56 (01): : 38 - 51
  • [5] MEG VERSUS EEG LOCALIZATION TEST USING IMPLANTED SOURCES IN THE HUMAN BRAIN
    COHEN, D
    CUFFIN, BN
    YUNOKUCHI, K
    MANIEWSKI, R
    PURCELL, C
    COSGROVE, GR
    IVES, J
    KENNEDY, JG
    SCHOMER, DL
    [J]. ANNALS OF NEUROLOGY, 1990, 28 (06) : 811 - 817
  • [6] COMPARISON OF SUBCORTICAL CORTICAL AND SCALP ACTIVITY USING CHRONICALLY INDWELLING ELECTRODES IN MAN
    COOPER, R
    WINTER, AL
    CROW, HJ
    WALTER, WG
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1965, 18 (03): : 217 - &
  • [8] EFFECTS OF LOCAL VARIATIONS IN SKULL AND SCALP THICKNESS ON EEGS AND MEGS
    CUFFIN, BN
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (01) : 42 - 48
  • [9] MEG AND ECOG LOCALIZATION ACCURACY TEST
    GHARIB, S
    SUTHERLING, WW
    NAKASATO, N
    BARTH, DS
    BAUMGARTNER, C
    ALEXOPOULOS, N
    TAYLOR, S
    ROGERS, RL
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1995, 94 (02): : 109 - 114
  • [10] ANATOMICAL CORRELATES FOR MAGNETOENCEPHALOGRAPHY - INTEGRATION WITH MAGNETIC-RESONANCE IMAGES
    HAMALAINEN, M
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1991, 12 : 29 - 32