Exchange of poorly functioning tunneled permanent hemodialysis catheters

被引:39
作者
Garofalo, RS
Zaleski, GX
Lorenz, JM
Funaki, B
Rosenblum, JD
Leef, JA
机构
[1] Univ Chicago Hosp, Dept Radiol, Chicago, IL 60637 USA
[2] Fox Valley, Radiol Associates, Oshkosh, WI 54901 USA
[3] Racine Radiologist Grp, Racine, WI 53405 USA
关键词
D O I
10.2214/ajr.173.1.10397118
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, The usefulness of exchanging poorly functioning tunneled permanent modialysis catheters in patients with end-stage renal disease was evaluated. MATERIALS AND METHODS. We retrospectively reviewed case histories of 51 consecutive patients who underwent 88 catheter exchanges because of poor flow rates. All hemodialysis catheters were initially placed by the radiology service using image guidance. Catheter exchanges were performed through the existing subcutaneous tract over two stiff hydrophilic guidewires and without additional interventions such as fibrin sheath stripping or venoplasty. Life table analysis was performed to evaluate catheter patency rates after initial placement (primary patency) and after multiple exchanges (secondary patency). RESULTS. The technical success rate for hemodialysis catheter exchange was 100%, Primary catheter patency was 42% at 60 days and 16% at 120 days. Secondary patency was 92% at 60 days and 82% at 120 days. The cumulative infection rate was 1.1 per 1000 catheter days, No complications from the procedure occurred. CONCLUSION. Catheter exchange is an effective means of prolonging catheter patency in patients with end-stage renal disease and limited central venous access.
引用
收藏
页码:155 / 158
页数:4
相关论文
共 20 条
[1]   NONINFECTIOUS COMPLICATIONS OF LONG-TERM CENTRAL VENOUS CATHETERS - RADIOLOGIC EVALUATION AND MANAGEMENT [J].
CASSIDY, FP ;
ZAJKO, AB ;
BRON, KM ;
REILLY, JJ ;
PEITZMAN, AB ;
STEED, DL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (04) :671-675
[2]   SUPERIORITY OF THE INTERNAL JUGULAR OVER THE SUBCLAVIAN ACCESS FOR TEMPORARY DIALYSIS [J].
CIMOCHOWSKI, GE ;
WORLEY, E ;
RUTHERFORD, WE ;
SARTAIN, J ;
BLONDIN, J ;
HARTER, H .
NEPHRON, 1990, 54 (02) :154-161
[3]   Fibrin sleeve stripping for salvage of failing hemodialysis catheters: Technique and initial results [J].
Crain, MR ;
Mewissen, MW ;
Ostrowski, GJ ;
PazFumagalli, R ;
Beres, RA ;
Wertz, RA .
RADIOLOGY, 1996, 198 (01) :41-44
[4]  
CURELARU ID, 1986, ACTA CHIR SCAND, V152, P583
[5]   Replacement of failing tunneled hemodialysis catheters through pre-existing subcutaneous tunnels: A comparison of catheter function and infection rates for de novo placements and over-the-wire exchanges [J].
Duszak, R ;
Haskal, ZJ ;
Thomas-Hawkins, C ;
Soulen, MC ;
Baum, RA ;
Shlansky-Goldberg, RD ;
Cope, C .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (02) :321-327
[6]   Radiologic placement of long-term hemodialysis catheters in occluded jugular or subclavian veins or through patent thyrocervical collateral veins [J].
Funaki, B ;
Zaleski, GX ;
Leef, JA ;
Rosenblum, JD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1194-1196
[7]   Transvenous removal of fibrin sheaths from tunneled hemodialysis catheters [J].
Haskal, ZJ ;
Leen, VH ;
ThomasHawkins, C ;
ShlanskyGoldberg, RD ;
Baum, RA ;
Soulen, MC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (04) :513-517
[8]  
HOSHAL VL, 1971, ARCH SURG-CHICAGO, V102, P353
[9]   Radiologic evaluation and management of malfunctioning long-term central vein catheters [J].
Kidney, DD ;
Nguyen, DT ;
Deutsch, LS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) :1251-1257
[10]   FUNCTIONAL RESTORATION OF OCCLUDED CENTRAL VENOUS CATHETERS - NEW INTERVENTIONAL TECHNIQUES [J].
KNELSON, MH ;
HUDSON, ER ;
SUHOCKI, PV ;
PAYNE, CS ;
SALLEE, DS ;
NEWMAN, GE .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 6 (04) :623-627