Stability analysis and design of automatic frequency control system for in vivo EPR spectroscopy

被引:21
作者
Hirata, H
Luo, ZW
机构
[1] Yamagata Univ, Dept Elect Engn, Yonezawa, Yamagata 9928510, Japan
[2] Yamagata Univ, Dept Biosyst Engn, Yonezawa, Yamagata 9928510, Japan
关键词
in vivo continuous-wave EPR; automatic frequency control; loop stability; phase margin; open-loop function; system bandwidth;
D O I
10.1002/mrm.1318
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Stability analysis and design of an automatic frequency control (AFC) system for in vivo continuous-wave EPR spectroscopy is described. The open-loop function of the feedback control system for the AFC was derived and the stability of the feedback loop systematically examined. A stability analysis of the system is demonstrated and a systematic design procedure is proposed. The design is started from the required system specifications (phase margin, steady-state error, and system bandwidth) and clear guidelines for designing an AFC system are given. A case study of the design is presented based on the specific needs of in vivo EPR measurements. A phase margin of 53 degrees, a steady-state error of 1.6%, and a system bandwidth of up to 1.8 kHz were obtained in the designed AFC system. The system specifications defined in advance are satisfied in this case study. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:1209 / 1215
页数:7
相关论文
共 15 条
[1]   Design and optimization of an automatic frequency control system for a radiofrequency electron paramagnetic resonance spectrometer [J].
Alecci, M ;
McCallum, SJ ;
Lurie, DJ .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1995, 117 (02) :272-277
[2]  
CARR JJ, 1997, MICROWAVES WIRELESS
[3]   DEVELOPMENT OF AN ELECTRONICALLY TUNABLE L-BAND RESONATOR FOR EPR SPECTROSCOPY AND IMAGING OF BIOLOGICAL SAMPLES [J].
CHZHAN, M ;
KUPPUSAMY, P ;
ZWEIER, JL .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 108 (01) :67-72
[4]   SENSITIVITY IMPROVEMENT OF A VARIAN E-109 ELECTRON-PARAMAGNETIC-RES SPECTROMETER WITH A LOW-NOISE MICROWAVE-AMPLIFIER [J].
DEXHEIMER, SL ;
KLEIN, MP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (05) :764-766
[5]  
EGAN WF, 1998, PHAS LOCK BASICS
[6]   Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy [J].
Hirata, H ;
Walczak, T ;
Swartz, HM .
JOURNAL OF MAGNETIC RESONANCE, 2000, 142 (01) :159-167
[7]   ELECTRON-PARAMAGNETIC-RES AUTOMATIC FREQUENCY CONTROL-CIRCUIT WITH FIELD-EFFECT TRANSISTOR (FET) MICROWAVE AMPLIFICATION [J].
HYDE, JS ;
GAJDZINSKI, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08) :1352-1356
[8]   DUAL DIODE DETECTOR FOR HOMODYNE EPR MICROWAVE BRIDGES [J].
KOSCIELNIAK, J ;
BERLINER, LJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (07) :2227-2230
[9]   300 MHz continuous wave electron paramagnetic resonance spectrometer for small animal in vivo imaging [J].
Koscielniak, J ;
Devasahayam, N ;
Moni, MS ;
Kuppusamy, P ;
Yamada, K ;
Mitchell, JB ;
Krishna, MC ;
Subramanian, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (11) :4273-4281
[10]   PHASE NOISE-REDUCTION OF A 19 GHZ VERACTOR-TUNED GUNN OSCILLATOR FOR ELECTRON-PARAMAGNETIC RESONANCE SPECTROSCOPY [J].
LESNIEWSKI, P ;
HYDE, JS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (08) :2248-2250