Third-generation biosensor for lactose based on newly discovered cellobiose dehydrogenase

被引:110
作者
Stoica, L
Ludwig, R
Haltrich, D
Gorton, L
机构
[1] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[2] BOKU Univ Nat Resources & Appl Life Sci Vienna, Dept Food Sci & Technol, Div Food Biotechnol, A-1190 Vienna, Austria
关键词
D O I
10.1021/ac050327o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper describes the principle and characteristics of a biosensor for lactose based on a third-generation design involving cellobiose dehydrogenase. As resulted from a previous comparative study (submitted manuscript), the novelty of this lactose biosensor is based on highly efficient direct electron transfer between two newly discovered cellobiose dehydrogenases (CDH), from the white rot fungi Trametes villosa and Phanerochaete sordida, and a solid spectrographic graphite electrode. CDH was immobilized on the electrode surface (0.073 cm(2)) by simple physical adsorption, and the CDH-modified electrode was next inserted into a wall-jet amperometric cell connected on-line to a flow injection setup (0.5 mL(.)min(-1)). The P. sordida CDH-based lactose biosensor, proved to be the better one, has a detection limit for lactose of 1 mu M, a sensitivity of 1100 mu A(.)mM(-1.)cm(-2), a response time of 4 s (the time required to obtain the maximum peak current), and a linear range from 1 to 100 mu M lactose (correlation coefficient 0.998). The simplicity of construction and analytical characteristics make this CDH-based lactose biosensor an excellent alternative to previous lactose biosensors reported in the literature or commercially available. The CDH-lactose sensor was used to quantify the content of lactose in pasteurized milk, buttermilk, and low-lactose milk, using the standard addition method. No effects of the samples matrixes were observed. The operational stability of the sensor was tested for 11 h by continuous injection of 100 mu M lactose (290 injections). The final signal of the sensor was maintained at 98% of its initial signal, with a low standard deviation of 1.72 (RSD 2.41%).
引用
收藏
页码:393 / 398
页数:6
相关论文
共 49 条
[1]   ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE [J].
APPELQVIST, R ;
MARKOVARGA, G ;
GORTON, L ;
TORSTENSSON, A ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :237-247
[2]   Cellobiose dehydrogenase - an extracellular fungal flavocytochrome [J].
Cameron, MD ;
Aust, SD .
ENZYME AND MICROBIAL TECHNOLOGY, 2001, 28 (2-3) :129-138
[3]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[4]   Biosensors for life quality -: Design, development and applications [J].
Castillo, J ;
Gáspár, S ;
Leth, S ;
Niculescu, M ;
Mortari, A ;
Bontidean, I ;
Soukharev, V ;
Dorneanu, SA ;
Ryabov, AD ;
Csöregi, E .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 102 (02) :179-194
[5]   Electrochemical studies on antioxidants in bovine milk [J].
Chen, J ;
Gorton, L ;
Åkesson, B .
ANALYTICA CHIMICA ACTA, 2002, 474 (1-2) :137-146
[6]  
Domínguez E, 2005, COMP ANAL C, V44, P429, DOI 10.1016/S0166-526X(05)44010-6
[7]   CELLOBIOSE OXIDASE CROSS-LINKED IN A REDOX POLYMER MATRIX AT AN ELECTRODE SURFACE - A NEW BIOSENSOR [J].
ELMGREN, M ;
LINDQUIST, SE ;
HENRIKSSON, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 341 (1-2) :257-273
[8]   A three-cascaded-enzymes biosensor to determine lactose concentration in raw milk [J].
Eshkenazi, I ;
Maltz, E ;
Zion, B ;
Rishpon, J .
JOURNAL OF DAIRY SCIENCE, 2000, 83 (09) :1939-1945
[9]   Direct electron transfer of heme- and molybdopterin cofactor-containing chicken liver sulfite oxidase on alkanethiol-modified gold electrodes [J].
Ferapontova, EE ;
Ruzgas, T ;
Gorton, L .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4841-4850
[10]  
FERAPONTOVA EE, IN PRESS ELECTROCHEM