A three-cascaded-enzymes biosensor to determine lactose concentration in raw milk

被引:48
作者
Eshkenazi, I
Maltz, E
Zion, B
Rishpon, J [1 ]
机构
[1] Tel Aviv Univ, Dept Mol Microbiol & Biotechnol, IL-69978 Ramat Aviv, Israel
[2] Agr Res Org, Volcani Ctr, Inst Agr Engn, IL-50250 Bet Dagan, Israel
关键词
lactose; biosensor; raw milk;
D O I
10.3168/jds.S0022-0302(00)75069-7
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The increasing demand for on-line measurement of milk composition directs science and industry to search for practical solutions, and biosensors may be a possibility. The specific objective of this work was to develop an electrochemical biosensor to determine lactose concentration in fresh raw milk. The sensor is based on serial reactions of three enzymes-beta-galactosidase, glucose oxidase, and horseradish peroxidase-immobilized on a glassy carbon electrode. The sequential enzymatic reactions increase the selectivity and sensitivity of the sensor. The sensor requires dilution of the raw milk and the addition of Et-aminosalicylic acid. Lactose concentrations in raw milk measured by the sensor were in good agreement with those measured by a reference laboratory using infrared technology. The results were obtained in milk samples that varied in fat and protein composition. From the results, we conclude that an electrochemical biosensor for determination of lactose concentration in fresh raw milk can be developed, and that the biosensor presented in this study maintained the qualities required for further development into an online sensor in the milking parlor.
引用
收藏
页码:1939 / 1945
页数:7
相关论文
共 26 条
[1]  
ABDULHAMID J, 1989, ANALYST, V14, P1587
[2]   AMPEROMETRIC ENZYME ELECTRODES .6. ENZYME ELECTRODES FOR SUCROSE AND LACTOSE [J].
ALBERY, WJ ;
KALIA, YN ;
MAGNER, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 325 (1-2) :83-93
[3]  
[Anonymous], 1980, ELECTROCHEMICAL METH
[4]   POLYETHYLENEIMINE IN IMMOBILIZATION OF BIOCATALYSTS [J].
BAHULEKAR, R ;
AYYANGAR, NR ;
PONRATHNAM, S .
ENZYME AND MICROBIAL TECHNOLOGY, 1991, 13 (11) :858-868
[5]  
BLUM IJ, 1991, BIOPROCESS TECHNOL, V15, P339
[6]  
BOYER DD, 1972, ENZYMES, V7, P646
[7]  
Cass A. E. G., 1990, BIOSENSORS PRACTICAL
[8]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[9]  
DYER N, 1991, ANAL BIOCHEM, V194, P16
[10]   Enzymatic membranes for determination of some disaccharides by means of an oxygen electrode [J].
Filipiak, M ;
Fludra, K ;
Gosciminska, E .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (04) :355-364