Prospective randomized comparison of oral sodium phosphate and polyethylene glycol lavage for colonoscopy preparation

被引:40
作者
Hwang, Kai-Lin [2 ,3 ]
Chen, William Tzu-Liang [1 ]
Hsiao, Koung-Hong [1 ]
Chen, Hong-Chang [1 ]
Huang, Ting-Ming [1 ]
Chiu, Chien-Ming [1 ]
Hsu, Ger-Haur [1 ]
机构
[1] ChangHua Christian Hosp, Div Colorectal Surg, Changhua 500, Taiwan
[2] Chung Shan Med Univ, Dept Publ Hlth, Taichung 402, Taiwan
[3] ChangHua Christian Hosp, Ctr Clin Trials, Changhua 500, Taiwan
关键词
Colonoscopy; Bowel preparation; Sodium phosphate; Polyethylene glycol;
D O I
10.3748/wjg.v11.i47.7486
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To compare the effectiveness, patient acceptability, and physical tolerability of two oral lavage solutions prior to colonoscopy in a Taiwanese population. METHODS: Eighty consecutive patients were randomized to receive either standard 4 L of polyethylene glycol (PEG) or 90 mL of sodium phosphate (NaP) in a split regimen of two 45 mL doses separated by 12 h, prior to colonoscopic evaluation. The primary endpoint was the percent of subjects who had completed the preparation. Secondary endpoints included colonic cleansing evaluated with an overall assessment and segmental evaluation, the tolerance and acceptability assessed by a self-administered structured questionnaire, and a safety profile such as any unexpected adverse events, electrolyte tests, physical exams, vital signs, and body weights. RESULTS: A significantly higher completion rate was found in the NaP group compared to the PEG group (84.2% vs 27.5%, P < 0.001). The amount of fluid suctioned was significantly less in patients taking NaP vs PEG (50.13+/-54.8 cc vs 121.13+/-115.4 cc, P < 0.001), even after controlling for completion of the oral solution (P = 0.031). The two groups showed a comparable overall assessment of bowel preparation with a rate of "good" or "excellent" in 78.9% of patients in the NaP group and 82.5% in PEG group (P = 0.778). Patients taking NaP tended to have significantly better colonic segmental cleansing relative to stool amount observed in the descending (94.7% vs 70%, P = 0.007) and transverse (94.6% vs 74.4%, P = 0.025) colon. Slightly more patients graded the taste of NaP as "good" or "very good" compared to the PEG patients (32.5% vs 12.5%; P = 0.059). Patients' willingness to take the same preparation in the future was 68.4% in the NaP compared to 75% in the PEG group (P = 0.617). There was a significant increase in serum sodium and a significant decrease in phosphate and chloride levels in NaP group on the day following the colonoscopy without any clinical sequelae. Prolonged (>24 h) hemodynamic changes were also observed in 20-35% subjects of either group. CONCLUSION: Both bowel cleansing agents proved to be similar in safety and effectiveness, while NaP appeared to be more cost-effective. After identifying and excluding patients with potential risk factors, sodium phosphate should become an alternative preparation for patients undergoing elective colonoscopy in the Taiwanese population. (C) 2005 The WJG Press and Elsevier Inc. All rights reserved.
引用
收藏
页码:7486 / 7493
页数:8
相关论文
共 36 条
[21]   Meta-analysis and cost comparison of polyethylene glycol lavage versus sodium phosphate for colonoscopy preparation [J].
Hsu, CW ;
Imperiale, TF .
GASTROINTESTINAL ENDOSCOPY, 1998, 48 (03) :276-282
[22]  
HUYNH T, 1995, AM J GASTROENTEROL, V90, P104
[23]   Efficacy and safety of sodium phosphate tablets compared with PEG solution in colon cleansing: two identically designed, randomized, controlled, parallel group, multicenter phase III trials [J].
Kastenberg, D ;
Chasen, R ;
Choudhary, C ;
Riff, D ;
Steinberg, S ;
Weiss, E ;
Wruble, L .
GASTROINTESTINAL ENDOSCOPY, 2001, 54 (06) :705-713
[24]  
KOLTS BE, 1993, AM J GASTROENTEROL, V88, P1218
[25]  
Law Wai-Lun, 2004, Asian J Surg, V27, P120, DOI 10.1016/S1015-9584(09)60324-9
[26]   COMPARISON OF 3 METHODS OF WHOLE BOWEL IRRIGATION [J].
MINERVINI, S ;
ALEXANDERWILLIAMS, J ;
DONOVAN, IA ;
BENTLEY, S ;
KEIGHLEY, MRB .
AMERICAN JOURNAL OF SURGERY, 1980, 140 (03) :400-402
[27]   Current practices of preoperative bowel preparation among North American colorectal surgeons [J].
Nichols, RL ;
Smith, JW ;
Garcia, RY ;
Waterman, RS ;
Holmes, JWC .
CLINICAL INFECTIOUS DISEASES, 1997, 24 (04) :609-619
[28]   Mechanical bowel preparation for elective colorectal surgery - A prospective, randomized, surgeon-blinded trial comparing sodium phosphate and polyethylene glycol-based oral lavage solutions [J].
Oliveira, L ;
Wexner, SD ;
Daniel, N ;
DeMarta, D ;
Weiss, EG ;
Nogueras, JJ ;
Bernstein, M .
DISEASES OF THE COLON & RECTUM, 1997, 40 (05) :585-591
[29]   Two liters of polyethylene glycol-electrolyte lavage solution versus sodium phosphate as bowel cleansing regimen for colonoscopy: A prospective randomized controlled trial [J].
Poon, CM ;
Lee, DWH ;
Mak, SK ;
Ko, CW ;
Chan, KC ;
Chan, KW ;
Sin, KS ;
Chan, ACW .
ENDOSCOPY, 2002, 34 (07) :560-563
[30]  
Reddy D Nageshwar, 2002, Indian J Gastroenterol, V21, P219