Lead phthalocyanine as a selective carrier for preparation of a cysteine-selective electrode

被引:1015
作者
Shahrokhian, S [1 ]
机构
[1] Sharif Univ Technol, Dept Chem, Tehran 11365, Iran
关键词
D O I
10.1021/ac010541m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel cysteine-selective electrode based on lead phthalocyanine (PbPc) as ionophore is described. The electrode was prepared by incorporating PbPc into a plasticized poly(vinyl chloride) (PVC) membrane, which was directly coated on the surface of a graphite electrode. This electrode shows high selectivity for the response to cysteine, as compared with many common inorganic anions, salicylate, and other kinds of amino acids. The influence of membrane composition, pH, and the effect of lipophilic cationic and anionic additives on the response characteristics of the electrode were investigated. The resulting sensor demonstrates nernstian response over a wide linear range of cysteine concentration (1 X 10(-6) to 5 X 10(-2) M). The electrode has a fast response time, micromolar detection limit (similar to1 x 10(-6) M), and good longterm stability (more than I month). The prepared electrode was used for determination of cysteine in a synthetic human serum sample, and very good recovery results were obtained over a wide concentration range of cysteine.
引用
收藏
页码:5972 / 5978
页数:7
相关论文
共 34 条
[1]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[2]   PVC-based Mn(III) porphyrin membrane coated graphite electrode for determination of histidine [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2502-2505
[3]   Thiocyanate-selective electrodes based on nickel and iron phthalocyanines [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICA CHIMICA ACTA, 1999, 402 (1-2) :137-143
[4]   PVC-based cobalt and manganese phthalocyanine coated graphite electrodes for determination of thiocyanate [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICAL LETTERS, 1999, 32 (14) :2737-2750
[5]  
[Anonymous], 1996, DICT ORGANIC COMPOUN, V4
[6]   AMPEROMETRY OF THIOLS IN A FLOW-INJECTION SYSTEM WITH A NICKEL-OXIDE ELECTRODE [J].
ARIKAWA, Y ;
HUBER, CO .
ANALYTICA CHIMICA ACTA, 1990, 229 (02) :191-195
[7]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890
[8]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[9]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[10]  
BELLI SL, 1986, ANAL LETT, V19, P403