Rapid cardiac imaging with turbo BRISK

被引:16
作者
Doyle, M
Walsh, EG
Foster, RE
Pohost, GM
机构
[1] Department of Medicine, Division of Cardiovascular Disease, University of Alabama at Birmingham, Birmingham, AL
[2] University of Alabama at Birmingham, D201J Diabet. Educ. and Res. Bldg., Birmingham, AL 35294-0012
关键词
fast imaging; cardiac imaging; k-space manipulation;
D O I
10.1002/mrm.1910370319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A variety of variable and constant rate, sparse sampling strategies have previously been proposed to rapidly image dynamically changing objects. The majority of these strategies compile a k-space data set for any given time point by substituting k-space data from the most recently sampled time positions (extracted from the sparsely sampled set), The BRISK technique, is a variable rate, sparse sampling technique which additionally incorporates an interpolation scheme to more accurately represent k-space data at positions which were not directly sampled, Here, strategies are introduced that allow turbo concepts to be incorporated with BRISK, Simulations are conducted to compare the efficacy of the turbo BRISK acquisition and processing strategy against a constant rate, sparse sampling strategy with direct substitution of the most recently acquired k-space lines. It is shown that turbo BRISK generates images of similar quality in approximately half the time as the uniform sampling rate, sparse sampling strategy. Data from turbo BRISK acquisitions of multicardiac phase image sets, obtained on a normal volunteer and cardiac patients are presented.
引用
收藏
页码:410 / 417
页数:8
相关论文
共 14 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   BLOCK REGIONAL INTERPOLATION SCHEME FOR K-SPACE (BRISK) - A RAPID CARDIAC IMAGING TECHNIQUE [J].
DOYLE, M ;
WALSH, EG ;
BLACKWELL, GG ;
POHOST, GM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) :163-170
[3]  
DOYLE M, 1994, P SMR 2 ANN M, P474
[4]   MR FLUOROSCOPY - INITIAL CLINICAL-STUDIES [J].
FARZANEH, F ;
RIEDERER, SJ ;
LEE, JN ;
TASCIYAN, T ;
WRIGHT, RC ;
SPRITZER, CE .
RADIOLOGY, 1989, 171 (02) :545-549
[5]   IMPROVED EJECTION FRACTION AND FLOW VELOCITY ESTIMATES WITH USE OF VIEW SHARING AND UNIFORM REPETITION TIME EXCITATION WITH FAST CARDIAC TECHNIQUES [J].
FOO, TKF ;
BERNSTEIN, MA ;
AISEN, AM ;
HERNANDEZ, RJ ;
COLLICK, BD ;
BERNSTEIN, T .
RADIOLOGY, 1995, 195 (02) :471-478
[6]   K-SPACE SUBSTITUTION - A NOVEL DYNAMIC IMAGING TECHNIQUE [J].
JONES, RA ;
HARALDSETH, O ;
MULLER, TB ;
RINCK, PA ;
OKSENDAL, AN .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :830-834
[7]   IS 300 MSEC TOO LONG FOR CARDIAC MR-IMAGING - FEASIBILITY STUDY DEMONSTRATING CHANGES IN LEFT-VENTRICULAR CROSS-SECTIONAL AREA WITH USE OF SINGLE-SHOT TURBOFLASH IMAGING [J].
MATSUDA, T ;
YAMADA, H ;
KIDA, M ;
SASAYAMA, S .
RADIOLOGY, 1994, 190 (02) :353-362
[8]   QUANTITATIVE-EVALUATION OF SEVERAL PARTIAL FOURIER RECONSTRUCTION ALGORITHMS USED IN MRI [J].
MCGIBNEY, G ;
SMITH, MR ;
NICHOLS, ST ;
CRAWLEY, A .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) :51-59
[9]   CARDIAC TAGGING WITH BREATH-HOLD CINE MRI [J].
MCVEIGH, ER ;
ATALAR, E .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :318-327
[10]   CONTINUOUS UPDATE WITH RANDOM ENCODING (CURE) - A NEW STRATEGY FOR DYNAMIC IMAGING [J].
PARRISH, T ;
HU, XP .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (03) :326-336