Measurement of heat flux and heat transfer coefficient during continuous cryogen spray cooling for laser dermatologic surgery

被引:37
作者
Aguilar, G [1 ]
Verkruysse, W
Majaron, B
Svaasand, LO
Lavernia, EJ
Nelson, JS
机构
[1] Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92162 USA
[2] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92162 USA
[3] Jozef Stefan Inst, SI-1000 Ljubljana, Slovenia
[4] Norwegian Univ Sci & Technol, Dept Phys & Elect, N-7034 Trondheim, Norway
[5] Univ Calif Irvine, Dept Chem Engn & Mat Sci, Irvine, CA 92162 USA
关键词
cryogen spurt; nozzles; port wine stain; skin cooling;
D O I
10.1109/2944.983307
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cryogen spray cooling (CSC) has been used for selective epidermal cooling of human skin during laser therapy of patients with port wine stain (PWS) birthmarks. Unfortunately, current commercial CSC devices do not provide optimal cooling selectivity and, therefore, provide insufficient epidermal protection for some PWS patients. To assist in the development of improved atomizing nozzle designs, a reliable method to quanti the CSC heat flux is needed. We introduce a novel method to determine the heat flux (q(s)) and heat transfer coefficient (h) at the surface of a sprayed object, based on measurements of steady-state temperature gradients along a thin copper rod during continuous cryogen spraying. For an atomizing nozzle of inner diameter d(N) = 0.7 mm, we found that q(s) varies from 15 to 130 W/cm(2) and h increases nonlinearly from 15000 to 35000 W/m(2 .)K in the explored range of surface temperatures (T-s, from -32 to -7degreesC). Values of q(s) obtained with a wider diameter nozzle (d(N) = 1.4 mm) are approximately twice as large than those of the narrow nozzle. The corresponding values of h are significantly higher (32 000-40 000 W/m(2 .)K) and almost independent of T, within the same temperature range. When combined with fast flashlamp photography (FFLP) of spray shapes and sprayed surfaces, the results demonstrate that the liquid cryogen layer, as deposited by finely atomized sprays from narrower nozzles, can significantly impair q(s). In contrast, the higher-momentum impact of coarser sprays from wider nozzles reduces the thickness of the liquid layer in the impact area and/or enhances convection within it, yielding a larger q(s).
引用
收藏
页码:1013 / 1021
页数:9
相关论文
共 27 条
[1]   Theoretical and experimental analysis of droplet diameter, temperature, and evaporation rate evolution in cryogenic sprays [J].
Aguilar, G ;
Majaron, B ;
Verkruysse, W ;
Zhou, Y ;
Nelson, JS ;
Lavernia, EJ .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (17) :3201-3211
[2]   Influence of nozzle-to-skin distance in cryogen spray cooling for dermatologic laser surgery [J].
Aguilar, G ;
Majaron, B ;
Pope, K ;
Svaasand, LO ;
Lavernia, EJ ;
Nelson, JS .
LASERS IN SURGERY AND MEDICINE, 2001, 28 (02) :113-120
[3]  
AGUILAR G, 2000, P ASME, V253, P189
[4]  
AGUILAR G, 2000, P 8 INT C LIQ AT SPR, P1041
[5]   Contact cooling of the skin [J].
Altshuler, GB ;
Zenzie, HH ;
Erofeev, AV ;
Smirnov, MZ ;
Anderson, RR ;
Dierickx, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (04) :1003-1023
[6]   Dynamic epidermal cooling in conjunction with laser treatment of port-wine stains: Theoretical and preliminary clinical evaluations [J].
Anvari, B ;
Milner, TE ;
Tanenbaum, BS ;
Kimel, S ;
Svaasand, LO ;
Nelson, JS .
LASERS IN MEDICAL SCIENCE, 1995, 10 (02) :105-112
[7]   A THEORETICAL-STUDY OF THE THERMAL RESPONSE OF SKIN TO CRYOGEN SPRAY COOLING AND PULSED-LASER IRRADIATION - IMPLICATIONS FOR TREATMENT OF PORT-WINE STAIN BIRTHMARKS [J].
ANVARI, B ;
TANENBAUM, BS ;
MILNER, TE ;
KIMEL, S ;
SVAASAND, LO ;
NELSON, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (09) :1451-1465
[8]  
Carslaw HS, 1959, CONDUCTION HEAT SOLI, Vsecond, P20
[9]   Cryogen spray cooling and higher fluence pulsed dye laser treatment improve port-wine stain clearance while minimizing epidermal damage [J].
Chang, CJ ;
Nelson, JS .
DERMATOLOGIC SURGERY, 1999, 25 (10) :767-772
[10]   Cryogen spray cooling for spatially selective photocoagulation of hemangiomas: A new methodology with preliminary clinical reports [J].
Chang, CJ ;
Anvari, B ;
Nelson, JS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 102 (02) :459-463