The value of setup portal films as an estimate of a patient's position throughout fractionated tangential breast irradiation: An on-line study

被引:9
作者
McGee, KP [1 ]
Fein, DA [1 ]
Hanlon, AL [1 ]
Schultheiss, TE [1 ]
Fowble, BL [1 ]
机构
[1] FOX CHASE CANC CTR,DEPT RADIAT ONCOL,PHILADELPHIA,PA 19111
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1997年 / 37卷 / 01期
关键词
EPID; portal setup; breast; setup reproducibility;
D O I
10.1016/S0360-3016(96)00463-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine if portal setup films are an accurate representation of a patient's position throughout the course of fractionated tangential breast irradiation. Methods and Materials: Thirteen patients undergoing external beam irradiation for T1-T2 infiltrating ductal carcinoma of the breast following excisional biopsy and axillary dissection were imaged using an on-line portal imaging device attached to a 6 MV linear accelerator, Medial and lateral tangential fields were imaged and a total of 139 fractions, 225 portal fields, and 4450 images were obtained, Interfractional and intrafractional variations for anatomical parameters including the central lung distance (CLD), central flash distance (CFD), and inferior central margin (ICM) were calculated from these images, A pooled estimate of the random error associated with a given treatment was determined by adding the interfractional and intrafractional standard deviations in quadrature, A 95% confidence level assigned a value of two standard deviations of the random error estimate, Central lung distance, CFD, and ICM distances were then measured for all portal setup films, Significant differences were defined as occurring when the simulation-setup difference was greater than the 95% confidence value. Results: Differences between setup portal and simulation films were less than their 95% confidence values in 70 instances indicating that in 90% of the time these differences are a result of random differences in daily treatment positioning. Conclusions: In 90% of cases tested, initial portal setup films are an accurate representation of a patients daily treatment setup. Copyright (C) 1997 Elsevier Science Inc.
引用
收藏
页码:223 / 228
页数:6
相关论文
共 22 条
[1]   ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS [J].
BALTER, JM ;
CHEN, GTY ;
PELIZZARI, CA ;
KRISHNASAMY, S ;
RUBIN, S ;
VIJAYAKUMAR, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01) :137-143
[2]  
BOYER AL, 1991, MED PHYS, V19, P1
[3]   WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS [J].
BYHARDT, RW ;
COX, JD ;
HORNBURG, A ;
LIERMANN, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10) :881-887
[4]   QUALITY ASSURANCE USING PORTAL IMAGING - THE ACCURACY OF PATIENT POSITIONING IN IRRADIATION OF BREAST-CANCER [J].
CREUTZBERG, CL ;
ALTHOF, VGM ;
HUIZENGA, H ;
VISSER, AG ;
LEVENDAG, PC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03) :529-539
[5]   ACCURACY OF PATIENT POSITIONING IN MANTLE FIELD IRRADIATION [J].
CREUTZBERG, CL ;
VISSER, AG ;
DEPORRE, PMZR ;
MEERWALDT, JH ;
ALTHOF, VGM ;
LEVENDAG, PC .
RADIOTHERAPY AND ONCOLOGY, 1992, 23 (04) :257-264
[6]  
Fein Douglas A., 1994, International Journal of Radiation Oncology Biology Physics, V30, P230, DOI 10.1016/0360-3016(94)90758-7
[7]   QUALITY-CONTROL IN RADIOTHERAPY - THE REDUCTION OF FIELD PLACEMENT ERRORS [J].
GRIFFITHS, SE ;
PEARCEY, RG ;
THOROGOOD, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (10) :1583-1588
[8]   IN-VIVO DETERMINATION OF THE ACCURACY OF FIELD MATCHING IN BREAST-CANCER IRRADIATION USING AN ELECTRONIC PORTAL IMAGING DEVICE [J].
HOLMBERG, O ;
HUIZENGA, H ;
IDZES, MHM ;
LEBESQUE, JV ;
VIJLBRIEF, RE ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1994, 33 (02) :157-166
[9]   ACCURACY IN RADIATION-FIELD ALIGNMENT IN HEAD AND NECK-CANCER - A PROSPECTIVE-STUDY [J].
HUIZENGA, H ;
LEVENDAG, PC ;
DEPORRE, PMZR ;
VISSER, AG .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (02) :181-187
[10]   THE EFFECT OF SETUP UNCERTAINTIES ON THE TREATMENT OF NASOPHARYNX CANCER [J].
HUNT, MA ;
KUTCHER, GJ ;
BURMAN, C ;
FASS, D ;
HARRISON, L ;
LEIBEL, S ;
FUKS, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02) :437-447