An MRAS-Based Diagnosis of Open-Circuit Fault in PWM Voltage-Source Inverters for PM Synchronous Motor Drive Systems

被引:276
作者
Jung, Shin-Myung [1 ]
Park, Jin-Sik [2 ]
Kim, Hag-Wone [3 ]
Cho, Kwan-Yuhl [3 ]
Youn, Myung-Joong [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon 305701, South Korea
[2] Samsung Electromech Co, CDS Circuit Technol Grp, Suwon 443743, Gyeonggi Do, South Korea
[3] Korea Natl Univ Transportat, Dept Control & Instrumentat Engn, Chungju 380702, Chungbuk, South Korea
关键词
Fault detection; fault diagnosis; fault identification; model reference adaptive system (MRAS); open-circuit fault; pulse-width modulated voltage-source inverter (PWM VSI); COMPENSATION;
D O I
10.1109/TPEL.2012.2212916
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
In this paper, a simple and low-cost open-circuit fault detection and identification method for a pulse-width modulated (PWM) voltage-source inverter (VSI) employing a permanent magnet synchronous motor is proposed. An open-circuit fault of a power switch in the PWM VSI changes the corresponding terminal voltage and introduces the voltage distortions to each phase voltage. The proposed open-circuit fault diagnosis method employs the model reference adaptive system techniques and requires no additional sensors or electrical devices to detect the fault condition and identify the faulty switch. The proposed method has the features of fast diagnosis time, simple structure, and being easily inserted to the existing control algorithms as a subroutine without major modifications. The simulations and experiments are carried out and the results show the effectiveness of the proposed method.
引用
收藏
页码:2514 / 2526
页数:13
相关论文
共 38 条
[1]
Fault-Tolerant Torque Control of BLDC Motors [J].
Aghili, Farhad .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (02) :355-363
[2]
Switching Function Model-Based Fast-Diagnostic Method of Open-Switch Faults in Inverters Without Sensors [J].
An, Qun-Tao ;
Sun, Li-Zhi ;
Zhao, Ke ;
Sun, Li .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (01) :119-126
[3]
[Anonymous], P IEEE INT S DIAGN E
[4]
[Anonymous], IEEE T IND CONTROL S
[5]
Automatic diagnosis and location of open-switch fault in brushless DC motor drives using wavelets and neuro-fuzzy systems [J].
Awadallah, MA ;
Morcos, MM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (01) :104-111
[6]
Markov Reliability Modeling for Induction Motor Drives Under Field-Oriented Control [J].
Bazzi, Ali M. ;
Dominguez-Garcia, Alejandro ;
Krein, Philip T. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (02) :534-546
[7]
Easy and Fast Sensor Fault Detection and Isolation Algorithm for Electrical Drives [J].
Berriri, Hanen ;
Naouar, Mohamed Wissem ;
Slama-Belkhodja, Ilhem .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (02) :490-499
[8]
Fault diagnostic in power system using wavelet transforms and neural networks [J].
Charfi, F. ;
Sellami, F. ;
Al-Haddad, K. .
2006 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-7, 2006, :1143-1148
[9]
Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System [J].
Choi, Ui-Min ;
Jeong, Hae-Gwang ;
Lee, Kyo-Beum ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (06) :2726-2739
[10]
An induction motor drive system with improved fault tolerance [J].
Corrêa, MBD ;
Jacobina, CB ;
da Silva, ERC ;
Lima, AMN .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (03) :873-879