A microfluidic chip based liquid-liquid extraction system with microporous membrane

被引:71
作者
Cai, ZX [1 ]
Fang, Q [1 ]
Chen, HW [1 ]
Fang, ZL [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310028, Peoples R China
基金
中国国家自然科学基金;
关键词
microfluidic chip; microporous membrane; liquid-liquid extraction;
D O I
10.1016/j.aca.2005.06.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A robust and simple approach for microfabricated chip based liquid-liquid extraction was developed for on-chip sample pretreatment. The chip based extraction system was composed of two microfabricated glass plates with a microporous membrane sandwiched in between. A simple bonding approach using epoxy was used to achieve bonding and scaling of the L-L extraction chip. Gravity was employed to drive the aqueous and organic flows through separate channels in the extraction system, separated by the membrane. During extraction, the analyte in an aqueous sample stream was transferred through the membrane into the organic stream. The fluorescence intensity of the analyte extracted into the organic stream was monitored in situ by a laser induced fluorescence detection system. The performance of the system was demonstrated using an aqueous solution of butyl rhodamine B (BRB) and isobutanol as sample and extractant, respectively. The system proved to be an efficient means for achieving chip based microporous membrane liquid-liquid extraction. The precision of fluorescence measurements was 1.5% R.S.D. (n = 4). A linear response range of I X 10(-7) to I X 10(-4) M BRB was obtained with a regression equation: l = 8.00 X 10(6) C+4.91. An enrichment factor of ca. 3 was obtained with an extraction efficiency of 69%. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:151 / 156
页数:6
相关论文
共 15 条
[1]  
AOTA A, 2003, P 7 INT C MIN CHEM B, P441
[2]   A high-throughput continuous sample introduction interface for microfluidic chip-based capillary electrophoresis systems [J].
Fang, Q ;
Xu, GM ;
Fang, ZL .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1223-1231
[3]   On-line membrane extraction liquid chromatography for monitoring semi-volatile organics in aqueous matrices [J].
Guo, XM ;
Mitra, S .
JOURNAL OF CHROMATOGRAPHY A, 2000, 904 (02) :189-196
[4]   Stabilization of liquid interface and control of two-phase confluence and separation in glass microchips by utilizing octadecylsilane modification of microchannels [J].
Hibara, A ;
Nonaka, M ;
Hisamoto, H ;
Uchiyama, K ;
Kikutani, Y ;
Tokeshi, M ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1724-1728
[5]   Chemicofunctional membrane for integrated chemical processes on a microchip [J].
Hisamoto, H ;
Shimizu, Y ;
Uchiyama, K ;
Tokeshi, M ;
Kikutani, Y ;
Hibara, A ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2003, 75 (02) :350-354
[6]   On-chip integration of neutral ionophore-based ion pair extraction reaction [J].
Hisamoto, H ;
Horiuchi, T ;
Tokeshi, M ;
Hibara, A ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1382-1386
[7]   Microporous membrane liquid-liquid extraction technique combined with gas chromatography mass spectrometry for the determination of organotin compounds [J].
Ndungu, K ;
Mathiasson, L .
ANALYTICA CHIMICA ACTA, 2000, 404 (02) :319-328
[8]   Microporous membrane liquid-liquid extraction coupled on-line with normal-phase liquid chromatography for the determination of cationic surfactants in river and waste water [J].
Norberg, J ;
Thordarson, E ;
Mathiasson, L ;
Jönsson, JÅ .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :523-529
[9]   AN UNSEGMENTED EXTRACTION SYSTEM FOR FLOW-INJECTION ANALYSIS [J].
SAHLESTROM, Y ;
KARLBERG, B .
ANALYTICA CHIMICA ACTA, 1986, 179 :315-323
[10]  
Shaw J, 2000, MESA MG, P371