A high-throughput continuous sample introduction interface for microfluidic chip-based capillary electrophoresis systems

被引:101
作者
Fang, Q [1 ]
Xu, GM [1 ]
Fang, ZL [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310028, Peoples R China
关键词
D O I
10.1021/ac010925c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of efficient sample introduction and pretreatment systems for microfluidic chip-based analytical systems is important for their application to real-life samples. In this work, world-to-chip interfacing was achieved by a novel flow-through sampling reservoir featuring a guided overflow design. The flow-through reservoir was fabricated on a 30 x 60 x 3 mm planar glass chip of crossed-channel design used for capillary electrophoresis separations. The 20-muL sample reservoir was produced from a section of plastic pipet tip and fixed at one end of the sampling channel. Sample change was performed by pumping 80-muL samples sandwiched between air segments at similar to0.48 mL/min flow rate through the flow-through reservoir, introduced from an access hole on the bottom side of the chip. A filter paper collar wrapped tightly around the reservoir guided the overflowing sample solution into a plastic trough surrounding the reservoir and then to waste. The performance of the system was demonstrated in the separation and determination of FITC-labeled arginine, glycine, phenylalanine, and glutamic acid with LIF detection, by continuously introducing a train of different samples through the system without electrical interruption. Employing a separation channel of 4 cm (2-cm effective separation length) and 1.4-kV separation voltage, maximum throughputs of 80/h were achieved with <4.1% carryover and precisions ranging from 1.5% for arginine to 2.6% RSD (n = 11) for glycine. The sampling system was tested in the continuous monitoring of the derivatizing process of amino acids by FITC over a period of 4 h, involving 166 analytical cycles. An outstanding overall precision of 4.8% RSD (n = 166) was achieved for the fluorescein internal standard.
引用
收藏
页码:1223 / 1231
页数:9
相关论文
共 29 条
  • [1] Attiya S, 2001, ELECTROPHORESIS, V22, P318, DOI 10.1002/1522-2683(200101)22:2<318::AID-ELPS318>3.0.CO
  • [2] 2-G
  • [3] An integrated nanoliter DNA analysis device
    Burns, MA
    Johnson, BN
    Brahmasandra, SN
    Handique, K
    Webster, JR
    Krishnan, M
    Sammarco, TS
    Man, PM
    Jones, D
    Heldsinger, D
    Mastrangelo, CH
    Burke, DT
    [J]. SCIENCE, 1998, 282 (5388) : 484 - 487
  • [4] Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)
    Duffy, DC
    McDonald, JC
    Schueller, OJA
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 4974 - 4984
  • [5] GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS
    EFFENHAUSER, CS
    MANZ, A
    WIDMER, HM
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (19) : 2637 - 2642
  • [6] Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips
    Effenhauser, CS
    Bruin, GJM
    Paulus, A
    Ehrat, M
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (17) : 3451 - 3457
  • [7] Sequential injection sample introduction microfluidic-chip based capillary electrophoresis system
    Fang, Q
    Wang, FR
    Wang, SL
    Liu, SS
    Xu, SK
    Fang, ZL
    [J]. ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) : 27 - 37
  • [8] Fang Z., 1993, FLOW INJECTION SEPAR
  • [9] Combination of flow injection with capillary electrophoresis - Part 7. Microchip capillary electrophoresis system with flow injection sample introduction and amperometric detection
    Fu, CG
    Fang, ZL
    [J]. ANALYTICA CHIMICA ACTA, 2000, 422 (01) : 71 - 79
  • [10] MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP
    HARRISON, DJ
    FLURI, K
    SEILER, K
    FAN, ZH
    EFFENHAUSER, CS
    MANZ, A
    [J]. SCIENCE, 1993, 261 (5123) : 895 - 897