Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions

被引:232
作者
Yeow, KM
See, LC
Lui, KW
Lin, MC
Tsao, TCY
Ng, KF
Liu, HP
机构
[1] Chang Gung Univ, Dept Diagnost Radiol, Chang Gung Mem Hosp, Tao Yuan 333, Taiwan
[2] Chang Gung Univ, Dept Publ Hlth, Chang Gung Mem Hosp, Tao Yuan 333, Taiwan
[3] Chang Gung Univ, Dept Pulm & Crit Care Med, Chang Gung Mem Hosp, Tao Yuan 333, Taiwan
[4] Chang Gung Univ, Dept Pathol, Chang Gung Mem Hosp, Tao Yuan 333, Taiwan
[5] Chang Gung Univ, Dept Cardiovasc Thorac Surg, Chang Gung Mem Hosp, Tao Yuan 333, Taiwan
关键词
computed tomography (CT); guidance; lung; biopsy; pneumothorax;
D O I
10.1016/S1051-0443(07)61556-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate risk factors for pneumothorax and bleeding,after computed tomography (CT)-guided percutaneous coaxial cutting needle biopsy of lung lesions. MATERIALS AND METHODS: This study involved 117 consecutive, patients with 117 intrapulmonary lesions. Statistical analysis of factors related to patient characteristics, lung lesions, and biopsy technique was performed to determine possible contribution to the occurrence of pneumothorax and bleeding. Interactions between related factors were considered to prevent colinearity. RESULTS: Pneumothorax occurred in 12% (14 of 117) of patients. Needle aspiration of two moderate asymptomatic pneumothoraces were performed; there was no chest tube insertion. Lesion depth (P = .0097), measured from the pleural puncture site to the edge of the intrapulmonary lesion along the needle path, was the single significant predictor of pneumothorax. The highest risk of pneumothorax occurred in subpleural lesions 2 cm or shorter in depth (this represented 33% of lung lesions but caused 71% of all pneumothoraces; OR = 7.1; 95% Cl, 1.3-50.8). Bleeding presented as lung parenchyma hemorrhage and hemoptysis in 30 patients (26%). Hemoptysis occurred in four patients (3%). Univariate analysis identified lesion depth (P < .0001), lesion size (P < .015), and pathology type (P = .007) as risk factors for bleeding. Multivariate logistic regression analysis identified lesion depth as the most important risk factor, with the highest bleeding risk for lesions more than 2 cm deep (14% of lesions caused 46% of all bleeding; OR = 17.3; 95% CI, 3.3-121.4). CONCLUSIONS: In CT-guided coaxial cutting needle biopsy, lesion depth is the single predictor for risk of pneumothorax, which occurs at the highest rate in subpleural lesions. Increased risk of bleeding occurs in lesions deeper than 2 cm.
引用
收藏
页码:1305 / 1312
页数:8
相关论文
共 30 条
[1]  
BERQUIST TH, 1980, MAYO CLIN PROC, V55, P475
[2]   Pneumothorax size: Correlation of supine anteroposterior with erect posteroanterior chest radiographs [J].
Choi, BG ;
Park, SH ;
Yun, EH ;
Chae, KO ;
Shinn, KS .
RADIOLOGY, 1998, 209 (02) :567-569
[3]   QUANTIFICATION OF PNEUMOTHORAX SIZE ON CHEST RADIOGRAPHS USING INTERPLEURAL DISTANCES - REGRESSION-ANALYSIS BASED ON VOLUME MEASUREMENTS FROM HELICAL CT [J].
COLLINS, CD ;
LOPEZ, A ;
MATHIE, A ;
WOOD, V ;
JACKSON, JE ;
RODDIE, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) :1127-1130
[4]   Image-guided automated needle biopsy of 106 thoracic lesions: a retrospective review of diagnostic accuracy and complication rates [J].
Connor, S ;
Dyer, J ;
Guest, P .
EUROPEAN RADIOLOGY, 2000, 10 (03) :490-494
[5]   Transthoracic needle aspiration biopsy: Variables that affect risk of pneumothorax [J].
Cox, JE ;
Chiles, C ;
McManus, CM ;
Aquino, SL ;
Choplin, RH .
RADIOLOGY, 1999, 212 (01) :165-168
[6]  
GAZELLE GS, 1999, CARDIOVASC INTERVENT, V14, P13
[7]   Insignificance of small loculated pneumothoraces after core biopsies of peripheral lung lesions using the Temno biopsy needle [J].
Herskowitz, MM ;
Delliturri, MR ;
Torrisi, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (04) :1163-1163
[8]   Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung [J].
Kazerooni, EA ;
Lim, FT ;
Mikhail, A ;
Martinez, FJ .
RADIOLOGY, 1996, 198 (02) :371-375
[9]   Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients [J].
Klein, JS ;
Salomon, G ;
Stewart, EA .
RADIOLOGY, 1996, 198 (03) :715-720
[10]   Percutaneous CT-guided biopsy of the lung: Comparison between aspiration and automated cutting needles using a coaxial technique [J].
Laurent, F ;
Latrabe, V ;
Vergier, B ;
Michel, P .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (04) :266-272