Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions

被引:232
作者
Yeow, KM
See, LC
Lui, KW
Lin, MC
Tsao, TCY
Ng, KF
Liu, HP
机构
[1] Chang Gung Univ, Dept Diagnost Radiol, Chang Gung Mem Hosp, Tao Yuan 333, Taiwan
[2] Chang Gung Univ, Dept Publ Hlth, Chang Gung Mem Hosp, Tao Yuan 333, Taiwan
[3] Chang Gung Univ, Dept Pulm & Crit Care Med, Chang Gung Mem Hosp, Tao Yuan 333, Taiwan
[4] Chang Gung Univ, Dept Pathol, Chang Gung Mem Hosp, Tao Yuan 333, Taiwan
[5] Chang Gung Univ, Dept Cardiovasc Thorac Surg, Chang Gung Mem Hosp, Tao Yuan 333, Taiwan
关键词
computed tomography (CT); guidance; lung; biopsy; pneumothorax;
D O I
10.1016/S1051-0443(07)61556-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate risk factors for pneumothorax and bleeding,after computed tomography (CT)-guided percutaneous coaxial cutting needle biopsy of lung lesions. MATERIALS AND METHODS: This study involved 117 consecutive, patients with 117 intrapulmonary lesions. Statistical analysis of factors related to patient characteristics, lung lesions, and biopsy technique was performed to determine possible contribution to the occurrence of pneumothorax and bleeding. Interactions between related factors were considered to prevent colinearity. RESULTS: Pneumothorax occurred in 12% (14 of 117) of patients. Needle aspiration of two moderate asymptomatic pneumothoraces were performed; there was no chest tube insertion. Lesion depth (P = .0097), measured from the pleural puncture site to the edge of the intrapulmonary lesion along the needle path, was the single significant predictor of pneumothorax. The highest risk of pneumothorax occurred in subpleural lesions 2 cm or shorter in depth (this represented 33% of lung lesions but caused 71% of all pneumothoraces; OR = 7.1; 95% Cl, 1.3-50.8). Bleeding presented as lung parenchyma hemorrhage and hemoptysis in 30 patients (26%). Hemoptysis occurred in four patients (3%). Univariate analysis identified lesion depth (P < .0001), lesion size (P < .015), and pathology type (P = .007) as risk factors for bleeding. Multivariate logistic regression analysis identified lesion depth as the most important risk factor, with the highest bleeding risk for lesions more than 2 cm deep (14% of lesions caused 46% of all bleeding; OR = 17.3; 95% CI, 3.3-121.4). CONCLUSIONS: In CT-guided coaxial cutting needle biopsy, lesion depth is the single predictor for risk of pneumothorax, which occurs at the highest rate in subpleural lesions. Increased risk of bleeding occurs in lesions deeper than 2 cm.
引用
收藏
页码:1305 / 1312
页数:8
相关论文
共 30 条
[11]   CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: Results with an automated 20-gauge coaxial cutting needle [J].
Laurent, F ;
Latrabe, V ;
Vergier, B ;
Montaudon, M ;
Vernejoux, JM ;
Dubrez, J .
CLINICAL RADIOLOGY, 2000, 55 (04) :281-287
[12]   Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: Incidence and risk factors [J].
Laurent, F ;
Michel, P ;
Latrabe, V ;
de Lara, MT ;
Marthan, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1049-1053
[13]   Intrapulmonary lesions: Percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle [J].
Lucidarme, O ;
Howarth, N ;
Finet, JF ;
Grenier, PA .
RADIOLOGY, 1998, 207 (03) :759-765
[14]   Should cutting needles replace needle aspiration of lung lesions? [J].
McLoud, TC .
RADIOLOGY, 1998, 207 (03) :569-570
[15]   PREDICTION OF PNEUMOTHORAX RATE IN PERCUTANEOUS NEEDLE ASPIRATION OF THE LUNG [J].
MILLER, KS ;
FISH, GB ;
STANLEY, JH ;
SCHABEL, SI .
CHEST, 1988, 93 (04) :742-745
[16]   Technical aspects of needle aspiration lung biopsy: A personal perspective [J].
Moore, EH .
RADIOLOGY, 1998, 208 (02) :303-318
[17]   EFFECT OF PATIENT POSITIONING AFTER NEEDLE ASPIRATION LUNG-BIOPSY [J].
MOORE, EH ;
LEBLANC, J ;
MONTESI, SA ;
RICHARDSON, ML ;
SHEPARD, JAO ;
MCLOUD, TC .
RADIOLOGY, 1991, 181 (02) :385-387
[18]   COAXIAL PERCUTANEOUS BIOPSY TECHNIQUE WITH AUTOMATED BIOPSY DEVICES - VALUE IN IMPROVING ACCURACY AND NEGATIVE PREDICTIVE VALUE [J].
MOULTON, JS ;
MOORE, PT .
RADIOLOGY, 1993, 186 (02) :515-522
[19]   Special techniques in CT-guided transthoracic needle biopsy [J].
Nashed, Z ;
Klein, JS ;
Zarka, MA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (06) :1665-1668
[20]   PERCUTANEOUS NEEDLE-BIOPSY OF LUNG - REPORT OF 2 FATAL COMPLICATIONS [J].
NORENBERG, R ;
CLAXTON, CP ;
TAKARO, T .
CHEST, 1974, 66 (02) :216-218