Use of Nb2O5-SiO2 in an automated on-line preconcentration system for determination of copper and cadmium by FAAS

被引:49
作者
da Silva, EL [1 ]
Ganzarolli, EM [1 ]
Carasek, E [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
FAAS; flow injection analysis; Nb2O5-SiO2;
D O I
10.1016/j.talanta.2003.09.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure for the determination of trace level of copper(II) and cadmium(II) by FAAS using an on-line preconcentration system has been proposed. In this system, copper and cadmium ions were adsorbed onto a minicolumn packed with silica gel modified with niobium(V) oxide (Nb2O5-SiO2), followed by nitric acid elution in reverse mode and determination on-line by flame atomic absorption spectrometry (AAS) without interference of the matrix. Chemical and flow variables as well as concomitant ions were studied in the developed procedure. The enrichment factor for copper(II) and cadmium(II) was 34.2 and 33.0, respectively, using a preconcentration time of 2 min. The limit of detection for copper(II) and cadmium(II) was 0.4, and 0.1 mug l(-1), respectively. The precision of the method, evaluated as the relative standard deviation in solutions containing 15 mug l(-1) of copper and 10 mug l(-1) of cadmium, by analyzing a series of seven replicates, was 1.8 and 1.6%, respectively. The accuracy was assessed through recovery experiments of certified material and water samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 28 条
[1]   Cobalt ultra-trace on-line preconcentration and determination using a PTFE turnings packed column and electrothermal atomic absorption spectrometry. Applications in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) :1330-1334
[2]   On-line solid phase extraction system using PTFE packed column for the flame atomic absorption spectrometric determination of copper in water samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2001, 54 (05) :935-942
[3]   Application of Nb2O5-SiO2 in pre-concentration and determination of copper and cadmium by flow system with flame atomic absorption spectrometry [J].
Budziak, D ;
da Silva, EL ;
de Campos, SD ;
Carasek, E .
MICROCHIMICA ACTA, 2003, 141 (3-4) :169-174
[4]   Flow injection determination of cobalt after its sorption onto polyurethane foam loaded with 2-(2-thiazolylazo)-p-cresol (TAC) [J].
Cassella, RJ ;
Salim, VA ;
Jesuíno, LS ;
Santelli, RE ;
Ferreira, SLC ;
de Carvalho, MS .
TALANTA, 2001, 54 (01) :61-67
[5]   DETERMINATION OF COPPER IN WATER AND RICE SAMPLES BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH FLOW-INJECTION ONLINE ADSORPTION PRECONCENTRATION USING A KNOTTED REACTOR [J].
CHEN, HW ;
XU, SK ;
FANG, ZL .
ANALYTICA CHIMICA ACTA, 1994, 298 (02) :167-173
[6]   STABILITY AND SURFACE-ACIDITY OF NIOBIUM(V) OXIDE GRAFTED ON A SILICA-GEL SURFACE [J].
DENOFRE, S ;
GUSHIKEM, Y ;
DECASTRO, SC ;
KAWANO, Y .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1993, 89 (07) :1057-1061
[7]   Determination of vanadium, manganese, silver and lead by graphite furnace atomic absorption spectrometry after preconcentration on silica-gel modified with 3-aminopropyltriethoxysilane [J].
Ekinci, C ;
Köklü, Ü .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (09) :1491-1495
[8]  
Fang Z., 1993, FLOW INJECTION SEPAR
[9]   AN EFFICIENT FLOW-INJECTION SYSTEM WITH ONLINE ION-EXCHANGE PRECONCENTRATION FOR THE DETERMINATION OF TRACE AMOUNTS OF HEAVY-METALS BY ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
RUZICKA, J ;
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :23-39
[10]   DETERMINATION OF CADMIUM, LEAD AND COPPER IN WATER SAMPLES BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH PRECONCENTRATION BY FLOW-INJECTION ONLINE SORBENT EXTRACTION [J].
FANG, ZL ;
GUO, TZ ;
WELZ, B .
TALANTA, 1991, 38 (06) :613-619