Immobilization of hemoglobin on zirconium dioxide nanoparticles for preparation of a novel hydrogen peroxide biosensor

被引:219
作者
Liu, SQ [1 ]
Dai, ZH [1 ]
Chen, HY [1 ]
Ju, HX [1 ]
机构
[1] Nanjing Univ, Inst Analyt Sci, Dept Chem, State Key Lab Coordinat Chem, Nanjing 210093, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
biosensors; electrocatalysis; hydrogen peroxide; hemoglobin; direct electron transfer; zirconium dioxide; thermal stability;
D O I
10.1016/j.bios.2003.08.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Direct electrochemistry and thermal stability of hemoglobin (Hb) immobilized on a nanoineter-sized zirconium dioxide (ZrO2) modified pyrolytic graphite (PG) electrode were studied. The immobilized Hb displayed a couple of stable and well-defined redox peaks with an electron transfer rate constant of (7.90 +/- 0.93) s(-1) and a formal potential of -0.361 V (-0.12 V versus NHE) in 0.1 M pH 7.0 PBS. Both nanometer-sized ZrO2 and dimethyl sulfoxide (DMSO) could accelerate the electron transfer between Hb and the electrode. Spectroscopy analysis of the Hb/ZrO2/DMSO film showed that the immobilized Hb could retain its natural structure. This modified electrode showed a high thermal stability up to 74 degreesC and an electrocatalytic activity to the reduction of hydrogen peroxide (H2O2) without the aid of an electron mediator. The electrocatalytic response showed a linear dependence on the H2O2 concentration ranging from 1.5 to 30.2 muM with a detection limit of 0.14 muM at 3sigma. The apparent Michaelis-Menten constant K-M(app) for H2O2 sensor was estimated to be (0.31 +/- 0.02) mM, showing a high affinity. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:963 / 969
页数:7
相关论文
共 38 条
[1]  
BOWERS LD, 1986, ANAL CHEM, V58, P513
[2]   Ordered electrochemically active films of hemoglobin, didodecyldimethylammonium ions, and clay [J].
Chen, XL ;
Hu, NF ;
Zeng, YH ;
Rusling, JF ;
Yang, J .
LANGMUIR, 1999, 15 (20) :7022-7030
[3]   Direct electron transfer for hemoglobin in surfactant films cast on carbon electrodes [J].
Ciureanu, M ;
Goldstein, S ;
Mateescu, MA .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1998, 145 (02) :533-541
[4]   Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes [J].
de Mattos, IL ;
Gorton, L ;
Ruzgas, T .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) :193-200
[5]   Electron-transfer reactivity and enzymatic activity of hemoglobin in a SP sephadex membrane [J].
Fan, CH ;
Wang, HY ;
Sun, S ;
Zhu, DX ;
Wagner, G ;
Li, GX .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :2850-2854
[6]   Direct electrochemistry of membrane-entrapped horseradish peroxidase. Part I. A voltammetric and spectroscopic study [J].
Ferri, T ;
Poscia, A ;
Santucci, R .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 44 (02) :177-181
[7]   Direct electrochemistry of membrane-entrapped horseradish peroxidase. Part II: Amperometric detection of hydrogen peroxide [J].
Ferri, T ;
Poscia, A ;
Santucci, R .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 45 (02) :221-226
[8]   A SPECTROPHOTOMETRIC STUDY OF IONIZATIONS IN METHAEMOGLOBIN [J].
GEORGE, P ;
HANANIA, G .
BIOCHEMICAL JOURNAL, 1953, 55 (02) :236-243
[9]   Direct electron transfer and characterization of hemoglobin immobilized on a Au colloid-cysteamine-modified gold electrode [J].
Gu, HY ;
Yu, AM ;
Chen, HY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 516 (1-2) :119-126
[10]   Direct electrochemistry of hemoglobin in egg-phosphatidylcholine films and its catalysis to H2O2 [J].
Han, XJ ;
Huang, WM ;
Jia, JB ;
Dong, SJ ;
Wang, EK .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (09) :741-746