Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes

被引:114
作者
de Mattos, IL [1 ]
Gorton, L [1 ]
Ruzgas, T [1 ]
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
基金
巴西圣保罗研究基金会;
关键词
Prussian Blue; screen-printed electrodes; amperometric sensor; biosensor;
D O I
10.1016/S0956-5663(02)00185-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Gold (An) and platinum (Pt) screen-printed electrodes were modified with Prussian Blue (PB) for the development of amperometric sensors selective for hydrogen peroxide detection. The sensors exhibited sensitivities towards H2O2 equal to 2 A M-1 cm(-2) for An and 1 A M-1 cm(-2) for Pt electrodes. The sensors were also employed as the basis for construction of glucose biosensors through further modification with crystallised glucose oxidase immobilised in a Nafion membrane. In order to improve the operational stability of the modified electrodes a buffer solution containing tetrabutylammonium toluene-4-sulfonate was used. The long-term performance of the sensors and biosensors were evaluated by continuous monitoring of hydrogen peroxide and glucose solutions (50 muM and 1 mM, respectively) in the flow-injection mode for 10 h. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 37 条
  • [1] Configurations used in the design of screen-printed enzymatic biosensors.: A review
    Albareda-Sirvent, M
    Merkoçi, A
    Alegret, S
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) : 153 - 163
  • [2] BARD AJ, 1980, ELECTROCHEMICAL METH, P44
  • [3] Development of screen-printed enzyme electrodes for the estimation of fish quality
    Chemnitius, GC
    Bilitewski, U
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1996, 32 (02) : 107 - 113
  • [4] ELECTROCHEMICAL STUDY OF MICROCRYSTALLINE SOLID PRUSSIAN BLUE PARTICLES MECHANICALLY ATTACHED TO GRAPHITE AND GOLD ELECTRODES - ELECTROCHEMICALLY INDUCED LATTICE RECONSTRUCTION
    DOSTAL, A
    MEYER, B
    SCHOLZ, F
    SCHRODER, U
    BOND, AM
    MARKEN, F
    SHAW, SJ
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (07) : 2096 - 2103
  • [5] Mediatorless biosensor for H2O2 based on recombinant forms of horseradish peroxidase directly adsorbed on polycrystalline gold
    Ferapontova, EE
    Grigorenko, VG
    Egorov, AM
    Börchers, T
    Ruzgas, T
    Gorton, L
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) : 147 - 157
  • [6] Glucose biosensor based on a reagentless graphite-epoxy screen-printable biocomposite
    Galan-Vidal, CA
    Munoz, J
    Dominguez, C
    Alegret, S
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 45 (01) : 55 - 62
  • [7] Amperometric sensor for hydrogen peroxide, based on Cu2O or CuO modified carbon paste electrodes
    Garjonyte, R
    Malinauskas, A
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (01): : 122 - 123
  • [8] Simultaneous determination of maltose and glucose using a screen-printed electrode system
    Ge, F
    Zhang, XE
    Zhang, ZP
    Zhang, XM
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) : 333 - 339
  • [9] On the use of screen- and ink-jet printing to produce amperometric enzyme electrodes for lactate
    Hart, AL
    Turner, APF
    Hopcroft, D
    [J]. BIOSENSORS & BIOELECTRONICS, 1996, 11 (03) : 263 - 270
  • [10] Studies towards a disposable screen-printed amperometric biosensor for progesterone
    Hart, JP
    Pemberton, RM
    Luxton, R
    Wedge, R
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (11) : 1113 - 1121