Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes

被引:114
作者
de Mattos, IL [1 ]
Gorton, L [1 ]
Ruzgas, T [1 ]
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
基金
巴西圣保罗研究基金会;
关键词
Prussian Blue; screen-printed electrodes; amperometric sensor; biosensor;
D O I
10.1016/S0956-5663(02)00185-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Gold (An) and platinum (Pt) screen-printed electrodes were modified with Prussian Blue (PB) for the development of amperometric sensors selective for hydrogen peroxide detection. The sensors exhibited sensitivities towards H2O2 equal to 2 A M-1 cm(-2) for An and 1 A M-1 cm(-2) for Pt electrodes. The sensors were also employed as the basis for construction of glucose biosensors through further modification with crystallised glucose oxidase immobilised in a Nafion membrane. In order to improve the operational stability of the modified electrodes a buffer solution containing tetrabutylammonium toluene-4-sulfonate was used. The long-term performance of the sensors and biosensors were evaluated by continuous monitoring of hydrogen peroxide and glucose solutions (50 muM and 1 mM, respectively) in the flow-injection mode for 10 h. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 37 条
  • [21] Screen-printed ruthenium dioxide electrodes for pH measurements
    Koncki, R
    Mascini, M
    [J]. ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) : 143 - 149
  • [22] Sol-gel-derived thick-film conductometric biosensor for urea determination in serum
    Lee, WY
    Kim, SR
    Kim, TH
    Lee, KS
    Shin, MC
    Park, JK
    [J]. ANALYTICA CHIMICA ACTA, 2000, 404 (02) : 195 - 203
  • [23] Chromium hexacyanoferrate based glucose biosensor
    Lin, MS
    Shih, WC
    [J]. ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) : 183 - 189
  • [24] Disposable DNA electrochemical sensor for hybridization detection
    Marrazza, G
    Chianella, I
    Mascini, M
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (01) : 43 - 51
  • [25] MATTOS IL, 2000, ANAL SCI, V16, P795, DOI DOI 10.2116/ANALSCI.16.795
  • [26] MATTOS IL, 2000, TALANTA, V52, P791
  • [27] MATTOS IL, 2001, TALANTA, V54, P963
  • [28] Wet and dry chemistry kits for total creatine kinase activity using a microfabricated, planar, small-volume, amperometric cell
    Nagy, G
    Xu, CX
    Buck, RP
    Lindner, E
    Neuman, MR
    Sprinkle, RH
    [J]. ANALYTICA CHIMICA ACTA, 1998, 377 (01) : 1 - 12
  • [29] Electrochemical metallisation of carbon electrodes
    O'Connell, PJ
    O'Sullivan, CK
    Guilbault, GG
    [J]. ANALYTICA CHIMICA ACTA, 1998, 373 (2-3) : 261 - 270
  • [30] Prussian Blue bulk modified screen-printed electrodes for H2O2 detection and for biosensors
    O'Halloran, MP
    Pravda, M
    Guilbault, GG
    [J]. TALANTA, 2001, 55 (03) : 605 - 611