Development of a fluorescent light technique for evaluating microdamage in bone subjected to fatigue loading

被引:33
作者
Huja, SS
Hasan, MS
Pidaparti, R
Turner, CH
Garetto, LP
Burr, DB
机构
[1] Indiana Univ, Sch Med, Dept Anat, Indianapolis, IN 46202 USA
[2] Indiana Univ, Sch Dent, Dept Oral Facial Dev, Indianapolis, IN 46204 USA
[3] Indiana State Univ, Dept Ind & Mech Technol, Indianapolis, IN USA
[4] Indiana Univ Purdue Univ, Dept Engn Mech, Indianapolis, IN 46202 USA
[5] Indiana Univ, Sch Med, Dept Orthoped Surg, Indianapolis, IN 46202 USA
[6] Indiana Univ, Sch Med, Dept Physiol & Biophys, Indianapolis, IN 46202 USA
[7] Indiana Univ Purdue Univ, Biomech & Biomat Res Ctr, Indianapolis, IN 46202 USA
关键词
microdamage; fatigue; bone; histomorphometry; endosseous implant;
D O I
10.1016/S0021-9290(99)00047-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new method using fluorescent light microscopy has been developed to visualize and evaluate bone microdamage, We report the findings of two different experiments with a common aim of comparing the fluorescent light technique to the brightfield method for quantifying microdamage in bone, In Experiment 1, 36 canine femurs were tested in four-point cyclic bending until they had lost between 5 and 43% of their stiffness. The loaded portion of the bone was stained en bloc with basic fuchsin for the presence of damage. Standard point counting techniques were used to calculate fractional damaged area (Dm.Ar = Cr.Ar/B.Ar, mm(2)/mm(2)) under brightfield and fluorescent microscopy. In Experiment 2, bone microdamage adjacent to endosseous implants, subjected to fatigue loading (150,000 cycles, 2 Hz and 37 degrees C) ex vivo was examined, The bone around the implant was either allowed to heal (adapted specimen) for 12 weeks after placement in dog mid-femoral diaphyses prior to testing or was loaded immediately to simulate non-healed bent: surrounding endosseous implants (non-adapted). Crack numerical density (Cr.Dn = Cr.N/B.Ar, #/mm(2)), crack surface density (Cr.S.Dn = Tt.Cr.Le/B.Ar, mm/mm(2)) and fractional damaged area were calculated separately by both techniques in the adapted and non-adapted specimens. In both Experiments 1 and 2, significantly more microdamage was detected by the fluorescent technique than by the brightfield method. Also, there was a trend towards higher intraobserver repeatability when using the fluorescent method. These results suggest that the brightfield technique underestimates microdamage accumulation and that the fluorescent technique better represents the actual amounts of microdamage present. The results demonstrate that the fluorescent method provides an accurate and precise approach for bone microdamage evaluation, and that it improves the prediction of stiffness loss from damage accumulation. (C) 1999 Elsevier Science Ltd, All rights reserved.
引用
收藏
页码:1243 / 1249
页数:7
相关论文
共 35 条
[1]   Does microdamage accumulation affect the mechanical properties of bone? [J].
Burr, DB ;
Turner, CH ;
Naick, P ;
Forwood, MR ;
Ambrosius, W ;
Hasan, MS ;
Pidaparti, R .
JOURNAL OF BIOMECHANICS, 1998, 31 (04) :337-345
[2]   ALTERATIONS TO THE EN-BLOC BASIC FUCHSIN STAINING PROTOCOL FOR THE DEMONSTRATION OF MICRODAMAGE PRODUCED IN-VIVO [J].
BURR, DB ;
HOOSER, M .
BONE, 1995, 17 (04) :431-433
[3]   Bone microdamage acid skeletal fragility in osteoporotic and stress fractures [J].
Burr, DB ;
Forwood, MR ;
Fyhrie, DP ;
Martin, B ;
Schaffler, MB ;
Turner, CH .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (01) :6-15
[4]   VALIDITY OF THE BULK-STAINING TECHNIQUE TO SEPARATE ARTIFACTUAL FROM INVIVO BONE MICRODAMAGE [J].
BURR, DB ;
STAFFORD, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (260) :305-308
[5]  
BURR DB, 1993, CALCIF TISSUE INT S1, V53, P75
[6]   COMPACT BONE FATIGUE DAMAGE .1. RESIDUAL STRENGTH AND STIFFNESS [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BIOMECHANICS, 1977, 10 (5-6) :325-337
[7]   A CUMULATIVE DAMAGE MODEL FOR BONE-FRACTURE [J].
CARTER, DR ;
CALER, WE .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (01) :84-90
[8]   Age-related differences in post-yield damage in human cortical bone. Experiment and model [J].
Courtney, AC ;
Hayes, WC ;
Gibson, LJ .
JOURNAL OF BIOMECHANICS, 1996, 29 (11) :1463-1471
[9]   Three-dimensional confocal images of microdamage in cancellous bone [J].
Fazzalari, NL ;
Forwood, MR ;
Manthey, BA ;
Smith, K ;
Kolesik, P .
BONE, 1998, 23 (04) :373-378
[10]   SOME VISCO-PLASTIC CHARACTERISTICS OF BOVINE AND HUMAN CORTICAL BONE [J].
FONDRK, M ;
BAHNIUK, E ;
DAVY, DT ;
MICHAELS, C .
JOURNAL OF BIOMECHANICS, 1988, 21 (08) :623-630