Metallomesogenic stationary phase for open-tubular capillary electrochromatography

被引:16
作者
Chen, JL [1 ]
机构
[1] Chung Shan Med Univ, Dept Occupat Safety & Hlth, Taichung 40201, Taiwan
关键词
amino acid; metallomesogen; open-tubular capillary electrochromatography; phthalate; stationary phase;
D O I
10.1002/elps.200500628
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A synthetic coppermesogenic polymer is prepared and then covalently bonded to the siloxane-based deactivated column as the stationary phases of open-tubular CEC with essentially high phase ratio. The EOF generated from the modified phase is surveyed through conventional aqueous buffers and hydroorganic mobile phases. Zeta potentials, which are computed from the EOF data and the ratio of dielectric constant to viscosity, are plotted as a function of pH, ionic molarity, and compositional range. These plots responsible for the electroosmotic characteristic of the bonded phases are found to be like those of bare fused-silica or deactivated columns through decreasing or increasing the ACN content in the mobile phase, respectively. This two-phase characteristic is basically derived from the polymeric configuration with carboxylato ligands attached onto the polysiloxane backbone. Phthalates and amino acids are suitable probes to examine the two phenomena, more-polar and less-polar mediums, respectively, and to judge whether the chromatographic retention is the major source of separation mechanism. With the mixing modes of Lewis acid-base interaction, dispersive force, and shape discrimination, the chromatographic partition adequately accomplishes the uneasily resolved separations by only CZE mode, although the electrophoretic migration is truly somewhat involved.
引用
收藏
页码:729 / 735
页数:7
相关论文
共 29 条
[1]   Thermodynamic characterization of a metallomesogenic stationary phase in gas chromatography [J].
Chen, JL ;
Liu, CY .
ANALYTICA CHIMICA ACTA, 2005, 548 (1-2) :73-78
[2]   Preparation and evaluation of nickelmesogen for micropacked gas chromatography [J].
Chou, CT ;
Pai, YF ;
Lin, CC ;
Misra, TK ;
Liu, CY .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1043 (02) :255-263
[3]  
Dawson GB, 2004, J CHROMATOGR A, V1047, P299, DOI 10.1016/j.chroma.2004.06.091
[4]   Application of open tubular electrochromatography for acidic and basic analytes [J].
Dube, S ;
Smith, RM .
CHROMATOGRAPHIA, 2003, 57 (7-8) :485-492
[5]  
Epperson JD, 2001, ELECTROPHORESIS, V22, P771, DOI 10.1002/1522-2683(200102)22:4<771::AID-ELPS771>3.0.CO
[6]  
2-#
[7]   Recent highlights in stationary phase design for open-tubular capillary electrochromatography [J].
Guihen, E ;
Glennon, JD .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) :67-81
[8]   Metallomesogens as stationary phases for ligand exchange gas chromatography .1. The use of nickel and zinc complexes of 4-decanoxydithiobenzoic acid for the separation of polycyclic aromatic hydrocarbons and dialkyl sulfides [J].
Hu, CC ;
Liu, CY .
ANALYTICA CHIMICA ACTA, 1996, 332 (01) :23-30
[9]   EVALUATION OF SURFACE-BONDED POLYETHYLENE-GLYCOL AND POLYETHYLENE IMINE IN CAPILLARY ELECTROPHORESIS [J].
HUANG, MX ;
VORKINK, WP ;
LEE, ML .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1992, 4 (02) :135-143
[10]   Open-tubular capillary electrochromatography using a polymeric surfactant coating [J].
Kamande, MW ;
Kapnissi, CP ;
Zhu, XF ;
Akbay, C ;
Warner, IM .
ELECTROPHORESIS, 2003, 24 (06) :945-951