Simultaneous determination of everolimus and cyclosporine concentrations by HPLC with ultraviolet detection

被引:36
作者
Baldelli, S [1 ]
Zenoni, S [1 ]
Merlini, S [1 ]
Perico, N [1 ]
Cattaneo, D [1 ]
机构
[1] Osped Riuniti Bergamo, Mario Negri Inst Pharmacol Res, Dept Med & Transplantat, I-24125 Bergamo, Italy
关键词
HPLC; cyclosporine; everolimus; therapeutic drug monitoring;
D O I
10.1016/j.cca.2005.07.019
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
In the clinical practice of organ transplantation everolimus (RAD) is used in combination with cyclosporine (CsA), the most common antirejection agent. Both drugs show a narrow therapeutic window, which requires strict monitoring of their blood concentration. Simple methods for simultaneous measurement of RAD and CsA concentration are needed. As we have recently developed an HPLC-UV assay for RAD determination, we decided to implement it to allow concomitant measurement of CsA. The within- and between-day coefficients of variation of the measurement were less than 12.1% for RAD and 9.8% for CsA. The within- and between-day inaccuracy of quality control samples were less than 9.7% for RAD and less than 4.9% for CsA. The method was found accurate and precise and useful for simultaneous therapeutic monitoring of the two drugs. (C) 2005 Elsevier B.V All rights reserved.
引用
收藏
页码:354 / 358
页数:5
相关论文
共 20 条
[1]   High-performance liquid chromatography with ultraviolet detection for therapeutic drug monitoring of everolimus [J].
Baldelli, S ;
Murgia, S ;
Merlini, S ;
Zenoni, S ;
Perico, N ;
Remuzzi, G ;
Cattaneo, D .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2) :99-105
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   High-throughput semi-automated 96-well liquid/liquid extraction and liquid chromatography/mass spectrometric analysis of everolimus (RAD 001) and cyclosporin a (CsA) in whole blood [J].
Brignol, N ;
McMahon, LM ;
Luo, S ;
Tse, FLS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) :898-907
[4]   Comparison of different cyclosporine immunoassays to monitor C0 and C2 blood levels from kidney transplant recipients:: Not simply overestimation [J].
Cattaneo, D ;
Zenoni, S ;
Murgia, B ;
Merlini, S ;
Baldelli, S ;
Perico, N ;
Gotti, E ;
Ottomano, C ;
Crippa, A ;
Remuzzi, G .
CLINICA CHIMICA ACTA, 2005, 355 (1-2) :153-164
[5]  
DEBRUYN CSV, 1986, CUMULATIVE SUM TESTS, P1
[6]   Immunosuppressive drugs for kidney transplantation [J].
Halloran, PF .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (26) :2715-2729
[7]   Therapeutic drug monitoring of immunosuppressive drugs in kidney transplantation [J].
Holt, DW .
CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2002, 11 (06) :657-663
[8]   LC/ESI-MS allows simultaneous and specific quantification of SDZ RAD and cyclosporine, including groups of their metabolites in human blood [J].
Kirchner, GI ;
Vidal, C ;
Winkler, M ;
Mueller, L ;
Jacobsen, W ;
Franzke, A ;
Sewing, KF .
THERAPEUTIC DRUG MONITORING, 1999, 21 (01) :116-122
[9]   Simultaneous determination of four immunosuppressants by means of high speed and robust on-line solid phase extraction-high performance liquid chromatography-tandem mass spectrometry [J].
Koal, T ;
Deters, M ;
Casetta, B ;
Kaever, V .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (02) :215-222
[10]   Influence of delayed initiation of cyclosporine on everolimus pharmacokinetics in de novo renal transplant patients [J].
Kovarik, JM ;
Dantal, J ;
Civati, G ;
Rizzo, G ;
Rouilly, M ;
Bettoni-Ristic, O ;
Rordorf, C .
AMERICAN JOURNAL OF TRANSPLANTATION, 2003, 3 (12) :1576-1580