A multiresolution image based approach for correction of partial volume effects in emission tomography

被引:90
作者
Boussion, N [1 ]
Hatt, M [1 ]
Lamare, F [1 ]
Bizais, Y [1 ]
Turzo, A [1 ]
Rest, CCL [1 ]
Visvikis, D [1 ]
机构
[1] CHU Morvan, INSERM, Lab Traitement Informat Med, U650, Brest, France
关键词
D O I
10.1088/0031-9155/51/7/016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission tomography. They lead to a loss of signal in tissues of size similar to the point spread function and induce activity spillover between regions. Although PVE can be corrected for by using algorithms that provide the correct radioactivity concentration in a series of regions of interest (ROIs), so far little attention has been given to the possibility of creating improved images as a result of PVE correction. Potential advantages of PVE-corrected images include the ability to accurately delineate functional volumes as well as improving tumour-to-background ratio, resulting in an associated improvement in the analysis of response to therapy studies and diagnostic examinations, respectively. The objective of our study was therefore to develop a methodology for PVE correction not only to enable the accurate recuperation of activity concentrations, but also to generate PVE-corrected images. In the multiresolution analysis that we define here, details of a high-resolution image H (MRI or CT) are extracted, transformed and integrated in a low-resolution image L (PET or SPECT). A discrete wavelet transform of both H and L images is performed by using the 'a trous' algorithm, which allows the spatial frequencies (details, edges, textures) to be obtained easily at a level of resolution common to H and L. A model is then inferred to build the lacking details of L from the high-frequency details in H. The process was successfully tested on synthetic and simulated data, proving the ability to obtain accurately corrected images. Quantitative PVE correction was found to be comparable with a method considered as a reference but limited to ROI analyses. Visual improvement and quantitative correction were also obtained in two examples of clinical images, the first using a combined PET/CT scanner with a lymphoma patient and the second using a FDG brain PET and corresponding T1-weighted MRI in an epileptic patient.
引用
收藏
页码:1857 / 1876
页数:20
相关论文
共 41 条
[21]   Multisensor Fusion and Integration: Approaches, Applications, and Future Research Directions [J].
Luo, Ren C. ;
Yih, Chih-Chen ;
Su, Kuo Lan .
IEEE SENSORS JOURNAL, 2002, 2 (02) :107-119
[22]   A THEORY FOR MULTIRESOLUTION SIGNAL DECOMPOSITION - THE WAVELET REPRESENTATION [J].
MALLAT, SG .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1989, 11 (07) :674-693
[23]  
Matsuda H, 2003, J NUCL MED, V44, P1243
[24]   CORRECTION OF PET DATA FOR PARTIAL VOLUME EFFECTS IN HUMAN CEREBRAL-CORTEX BY MR IMAGING [J].
MELTZER, CC ;
LEAL, JP ;
MAYBERG, HS ;
WAGNER, HN ;
FROST, JJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) :561-570
[25]  
Meltzer CC, 1999, J NUCL MED, V40, P2053
[26]   MEASUREMENT OF RADIOTRACER CONCENTRATION IN BRAIN GRAY-MATTER USING POSITRON EMISSION TOMOGRAPHY - MRI-BASED CORRECTION FOR PARTIAL VOLUME EFFECTS [J].
MULLERGARTNER, HW ;
LINKS, JM ;
PRINCE, JL ;
BRYAN, RN ;
MCVEIGH, E ;
LEAL, JP ;
DAVATZIKOS, C ;
FROST, JJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1992, 12 (04) :571-583
[27]  
PETORIUS PH, 2004, P 51 SNM ANN M PHIL, P399
[28]  
Quarantelli M, 2004, J NUCL MED, V45, P192
[29]  
Ranchin T, 2000, PHOTOGRAMM ENG REM S, V66, P49
[30]   One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays [J].
Reader, AJ ;
Ally, S ;
Bakatselos, F ;
Manavaki, R ;
Walledge, RJ ;
Jeavons, AP ;
Julyan, PJ ;
Zhao, S ;
Hastings, DL ;
Zweit, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) :693-699