Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics

被引:158
作者
Carrier, JF
Archambault, L
Beaulieu, L
Roy, R
机构
[1] CHUQ Pavillon Hotel Dieu Quebec, Dept RadioOncol, Quebec City, PQ G1R 2J6, Canada
[2] CHUQ Pavillon Hotel Dieu Quebec, Ctr Rech Cancerol, Quebec City, PQ G1R 2J6, Canada
[3] Univ Laval, Dept Phys, Quebec City, PQ G1K 7P4, Canada
关键词
Monte Carlo; dosimetry; GEANT4; validation;
D O I
10.1118/1.1644532
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
GEANT4 (GEometry ANd Tracking 4) is an object-oriented Monte Carlo simulation toolkit that has been developed by a worldwide collaboration of scientists. It simulates the passage of particles through matter. In order to validate GEANT4 for medical physics applications, different simulations are conducted. The results are compared to published results based on three Monte Carlo codes widely used in medical physics: MCNP, EGS4, and EGSnrc. When possible, the simulation results are also compared to experimental data. Different geometries are tested (multilayer and homogeneous phantoms), different sources considered (point-source and broad parallel beam), and different primary particles simulated (photons and electrons) at different energies. For the heterogeneous media, there are notable differences between the Monte Carlo codes reaching up to over 5% in relative difference. For the monoenergetic electrons in a homogeneous medium, the difference between GEANT4 and the experimental measurements is similar to the difference between EGSnrc and the experimental measurements; for the depth-dose curves, the difference expressed as a fraction of the peak dose is always smaller than 4%. We conclude that GEANT4 is a promising Monte Carlo simulation toolkit for low-energy medical applications. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:484 / 492
页数:9
相关论文
共 25 条
[1]
GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]
AGOSTINELLI S, 1999, CERNOPEN99034
[3]
[Anonymous], 1997, UCRL 50400
[4]
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[5]
Briesmeister J., 1997, LA12625
[6]
Monte Carlo dose calculations in homogeneous media and at interfaces: A comparison between GEPTS, EGSnrc, MCNP, and measurements [J].
Chibani, O ;
Li, XA .
MEDICAL PHYSICS, 2002, 29 (05) :835-847
[7]
A SHORT ATLAS OF BETA-RAY SPECTRA [J].
CROSS, WG ;
ING, H ;
FREEDMAN, N .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (11) :1251-1260
[8]
DING GX, PIRS439 NRC
[9]
GIANI S, 1998, CERNLHCC9844
[10]
ITS - THE INTEGRATED TIGER SERIES OF ELECTRON PHOTON TRANSPORT CODES - VERSION 3.0 [J].
HALBLEIB, JA ;
KENSEK, RP ;
VALDEZ, GD .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :1025-1030