Comparison of automated nucleic acid extraction methods with manual extraction

被引:65
作者
Dundas, Nicola [1 ]
Leos, N. Kristine [1 ]
Mitui, Midori [1 ]
Revell, Paula [1 ,2 ]
Rogers, Beverly Barton [1 ,2 ]
机构
[1] Childrens Med Ctr, Dept Pathol, Dallas, TX 75235 USA
[2] Univ Texas SW Med Ctr Dallas, Dallas, TX 75390 USA
关键词
D O I
10.2353/jmoldx.2008.070149
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Automated nucleic acid extractors can improve work-flow and decrease variability in the clinical laboratory. We evaluated Qiagen EZ1 (Valencia, CA) and bioMericrux (Durham, NC) easyMAG extractors compared with Qiagen manual extraction using targets and matrices commonly available in the clinical laboratory. Pooled samples were spiked with various organisms, serially diluted, and extracted in duplicate. The organisms/matrices were Bordetella pertussis/bronchoalveolar lavage, herpes simplex virus II/cerebrospinal fluid, coxsackievirus A9/cerebrospinal fluid, BK virus/plasma, and Mycoplasma pneumoniae/endotracheal tube samples. Extracts were amplified in duplicate using real-time PCR assays, and amplification of the target at a cycle threshold of 35 using the manual method was used for comparison. Amplification efficiency of nucleic acids extracted by automated methods was similar to that by the manual method except for a loss of efficiency for M. pneumoniae in endotracheal tube samples. The EZ1 viral kit 2.0 gave better results for coxsackievirus A9 than the EZ1 viral kit version 1.0. At the lowest limit of detection (past a cycle threshold of 35), the easyMAG was more likely to produce amplifiable nucleic acid than were either the EZ1 or manual extraction. Operational complexity, defined as the number of manipulations required to obtain an extracted sample, was the lowest for the easyMAG. The easyMAG was the most expensive of the methods, followed by the EZ1 kit and manual extraction.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 11 条
[1]   Automated extraction of viral-pathogen RNA and DNA for high-throughput quantitative real-time PCR [J].
Beuselinck, K ;
van Ranst, M ;
van Eldere, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (11) :5541-5546
[2]   Evaluation of an automated high-volume extraction method for viral nucleic acids in comparison to a manual procedure with preceding enrichment [J].
Hourfar, MK ;
Schmidt, M ;
Seifried, E ;
Roth, WK .
VOX SANGUINIS, 2005, 89 (02) :71-76
[3]   Comparison of specimen processing and nucleic acid extraction by the swab extraction tube system versus the MagNA pure LC system for laboratory diagnosis of herpes simplex virus infections by LightCycler PCR [J].
Issa, NC ;
Espy, MJ ;
Uhl, JR ;
Harmsen, WS ;
Mandrekar, JN ;
Gullerud, RE ;
Davis, MD ;
Smith, TF .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (03) :1059-1063
[4]   Comparison of automated and manual nucleic acid extraction methods for detection of enterovirus RNA [J].
Knepp, JH ;
Geahr, MA ;
Forman, MS ;
Valsamakis, A .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (08) :3532-3536
[5]   Evaluation of NucliSens easyMAG for automated nucleic acid extraction from various clinical specimens [J].
Loens, K. ;
Bergs, K. ;
Ursi, D. ;
Goossens, H. ;
Ieven, M. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (02) :421-425
[6]   Multicenter comparison of nucleic acid extraction methods for detection of severe acute respiratory syndrome coronavirus RNA in stool specimens [J].
Petrich, A. ;
Mahony, J. ;
Chong, S. ;
Broukhanski, G. ;
Gharabaghi, F. ;
Johnson, G. ;
Louie, L. ;
Luinstra, K. ;
Willey, B. ;
Akhaven, P. ;
Chui, L. ;
Jamieson, F. ;
Louie, M. ;
Mazzulli, T. ;
Tellier, R. ;
Smieja, M. ;
Cai, W. ;
Chernesky, M. ;
Richardson, S. E. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (08) :2681-2688
[7]  
Read SJ, 2001, J CLIN PATHOL-MOL PA, V54, P86
[8]   Comparison of manual and automated nucleic acid extraction from whole-blood samples [J].
Riemann, Kathrin ;
Adamzik, Michael ;
Frauenrath, Stefan ;
Egensperger, Rupert ;
Schmid, Kurt W. ;
Brockmeyer, Norbert H. ;
Siffert, Winfried .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2007, 21 (04) :244-248
[9]   Reduced PCR sensitivity due to impaired DNA recovery with the MagNA pure LC total nucleic acid isolation kit [J].
Schuurman, T ;
van Breda, A ;
de Boer, R ;
Kooistra-Smid, M ;
Beld, M ;
Savelkoul, P ;
Boom, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (09) :4616-4622
[10]   Comparative evaluation of three commercial systems for nucleic acid extraction from urine specimens [J].
Tang, YW ;
Sefers, SE ;
Li, HJ ;
Kohn, DJ ;
Procop, GW .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (09) :4830-4833