A comparison of D-, E-, and F-speed conventional intraoral radiographic films in endodontic measurement

被引:8
作者
Sheaffer, JC
Eleazer, PD
Scheetz, JP
Clark, SJ
Farman, AG
机构
[1] Univ Louisville, Sch Dent, Louisville, KY 40292 USA
[2] Univ Alabama Birmingham, Sch Dent, Birmingham, AL 35487 USA
[3] Univ Louisville, Sch Dent, Grad Endodont Program, Louisville, KY USA
[4] Univ Louisville, Sch Dent, Div Radiol & Imaging Sci, Louisville, KY USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2002年 / 93卷 / 03期
关键词
D O I
10.1067/moe.2002.122336
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. We sought to compare observer measurement error and subjective ratings for International Standards Organization D-, E-, and F-speed direct exposure dental x-ray films used to determine endodontic working lengths, Methods. Radiographs were exposed to achieve a standard background density of approximately 2.0. Three human maxillary posterior teeth for which No. 10 K-files had been placed at various lengths within 4 canals were studied in a cadaver section. A total of 30 radiographs were used (10 froth each film type). Five licensed dentists excluding all authors viewed the radiographs independently and in random sequence. Distances from the file tips to the radiographic apices were measured and were compared with known lengths for error determination. The observing dentists also subjectively rated the images as desirable or undesirable. Statistical methods included a 3-factor ANOVA with Tukey honestly significant difference post hoc analysis to compare objective measurements and chi-square with respect to subjective ratings. Results. No significant differences were attributable to film speed grouping or observers (n > .05); however, there seas a specimen effect in that a significant difference was found in measurement accuracy among the 4 canals (P < .05). Differences in subjective ratings for the 3 film types were not statistically significant (P > .05). Conclusion. All 3 film types were similar in objective and subjective ratings. This being the case, the faster film is preferred to minimize the radiation dose to the patient.
引用
收藏
页码:337 / 340
页数:4
相关论文
共 10 条
[1]  
*AM NAT STAND I, 36651996 ANSIISO
[2]   An evaluation of Ektaspeed Plus film versus Ultraspeed film for endodontic working length determination [J].
Brown, R ;
Hadley, JN ;
Chambers, DW .
JOURNAL OF ENDODONTICS, 1998, 24 (01) :54-56
[3]   CLINICAL-EVALUATION OF EKTASPEED X-RAY-FILM FOR USE IN ENDODONTICS [J].
DONNELLY, JC ;
HARTWELL, GR ;
JOHNSON, WB .
JOURNAL OF ENDODONTICS, 1985, 11 (02) :90-94
[4]   RADIOVISIOGRAPHY VERSUS CONVENTIONAL RADIOGRAPHY FOR DETECTION OF SMALL INSTRUMENTS IN ENDODONTIC LENGTH DETERMINATION .1. IN-VITRO EVALUATION [J].
ELLINGSEN, MA ;
HARRINGTON, GW ;
HOLLENDER, LG .
JOURNAL OF ENDODONTICS, 1995, 21 (06) :326-331
[5]   AN EVALUATION OF KODAK EKTASPEED PERIAPICAL FILM FOR USE IN ENDODONTICS [J].
GIRSCH, WJ ;
MATTESON, SR ;
MCKEE, MN .
JOURNAL OF ENDODONTICS, 1983, 9 (07) :282-288
[6]   ENDODONTIC SUCCESS - WHOS READING RADIOGRAPH [J].
GOLDMAN, M ;
DARZENTA, N ;
PEARSON, AH .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1972, 33 (03) :432-&
[7]   RELIABILITY OF RADIOGRAPHIC INTERPRETATIONS [J].
GOLDMAN, M ;
PEARSON, AH ;
DARZENTA, N .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1974, 38 (02) :287-293
[8]   2 DENTAL-X-RAY FILMS COMPARED FOR RATER PREFERENCE USING ENDODONTIC VIEWS [J].
KLEIER, DJ ;
BENNER, SJ ;
AVERBACH, RE .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1985, 59 (02) :201-205
[9]  
MANSON-HING L R, 1962, Oral Surg Oral Med Oral Pathol, V15, P173, DOI 10.1016/0030-4220(62)90005-1
[10]   The effects of developer age on diagnostic accuracy: a study using assessment of endodontic file length [J].
Syriopoulos, K ;
Sanderink, GCH ;
Velders, XL ;
van Ginkel, FC ;
van der Stelt, PF .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (05) :311-315