Establishment of a standard assay method for human thrombomodulin and determination of the activity of the Japanese reference standard

被引:21
作者
Niimi, S
Oshizawa, T
Naotsuka, M
Ohba, S
Yokozawa, A
Murata, T
Hayakawa, T
机构
[1] Natl Inst Hlth Sci, Div Biol Chem & Biol, Setagaya Ku, Tokyo 1588501, Japan
[2] Mochida Pharmaceut Co Ltd, Pharmaceut Lab, Fujieda, Shizuoka 4268640, Japan
[3] Asahi Chem Ind Co Ltd, Lab Drug Formulat Res Inst Life Sci Res, Mifu Ku, Shizuoka 4102321, Japan
关键词
thrombomodulin; standard method; activity; reference standard;
D O I
10.1006/biol.2001.0318
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
This study was undertaken to establish a standard method for determination of the activity of human (h) thrombomodulin (TM). The reactions mainly consisted of formation of a h-TM and h-thrombin complex, activation of h-protein C by the complex and digestion of substrate by activated h-protein C, Linear time-dependent formation of p-nitroaniline from the substrate, S-2366, was observed up to 12 min during measurement of the activity of urinary h-TM (uh-TM) reference material by the standard method. Therefore, 10 minutes was established as the reaction time in the standard method, In the standard method, we defined the activity of h-TM forming 0(.)1 mumol of p-nitroaniline per min in the reaction as 1 JRS Unit. Recombinant h-TM (rh-TM) and uh-TM reference material gave rectilinear dose-response curves within a certain range of specific activities by their original methods in the standard method. The validity of the standard method was assessed based on the coefficients of variation (CV) obtained in the various measurements of h-TM, Intra-batch precision (CV) of h-thrombin and h-protein C was 2(.)90% and 6(.)57%, respectively, in the measurement of uh-TM activity. The intra-sample, inter-day, and inter-laboratory precision (CV) was 1(.)30%, 1(.)63% and 5(.)02%, respectively, in the measurement of the first Japanese reference standard for h-TM coded TJRS1. In these assays, the activity of the first Japanese standard was also determined and found to be 205 JRS units per ampoule. When the stability of the Japanese reference standard was assessed by measuring of the standard stored under various thermal conditions, the predicted loss of activity assuming monomolecular degradation according to the Arrhenius equation was less than 3(.)0% during 103 years at -20degreesC. These results indicate that the standard method is appropriate for determination of the activity of h-TM and that the Japanese reference standard for h-TM, whose activity was determined here, can be stored at -20degreesC for long periods without loss of activity. (C) 2002 The International Association for Biologicals.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 29 条
[1]
AOKI Y, 1994, THROMB HAEMOSTASIS, V71, P452
[2]
ANTITHROMBOTIC EFFECTS OF RECOMBINANT HUMAN SOLUBLE THROMBOMODULIN (RHS-TM) ON ARTERIOVENOUS SHUNT THROMBOSIS IN RATS [J].
AOKI, Y ;
TAKEI, R ;
MOHRI, M ;
GONDA, Y ;
GOMI, K ;
SUGIHARA, T ;
KIYOTA, T ;
YAMAMOTO, S ;
ISHIDA, T ;
MARUYAMA, I .
AMERICAN JOURNAL OF HEMATOLOGY, 1994, 47 (03) :162-166
[3]
CARSTENSEN JT, 1990, DRUG PHARM SCI, V43, P129
[4]
PROTEOLYTIC PROCESSING OF HUMAN FACTOR-VIII - CORRELATION OF SPECIFIC CLEAVAGES BY THROMBIN, FACTOR XA, AND ACTIVATED PROTEIN-C WITH ACTIVATION AND INACTIVATION OF FACTOR-VIII COAGULANT ACTIVITY [J].
EATON, D ;
RODRIGUEZ, H ;
VEHAR, GA .
BIOCHEMISTRY, 1986, 25 (02) :505-512
[5]
ESMON CT, 1983, BLOOD, V62, P1155
[6]
IDENTIFICATION OF AN ENDOTHELIAL-CELL COFACTOR FOR THROMBIN-CATALYZED ACTIVATION OF PROTEIN-C [J].
ESMON, CT ;
OWEN, WG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1981, 78 (04) :2249-2252
[7]
ESMON CT, 1982, J BIOL CHEM, V257, P7944
[8]
ESMON NL, 1983, J BIOL CHEM, V258, P2238
[9]
ESMON NL, 1982, J BIOL CHEM, V257, P859
[10]
FULCHER CA, 1984, BLOOD, V63, P486