Generation of physiological parameter sets for hip joint motions and loads during daily life activities for application in wear simulators of the artificial hip joint

被引:39
作者
Fabry, Christian [1 ]
Herrmann, Sven [1 ]
Kaehler, Michael [2 ]
Klinkenberg, Ernst-Dieter [3 ]
Woernle, Christoph [2 ]
Bader, Rainer [1 ]
机构
[1] Univ Med Rostock, Dept Orthopaed, Biomech & Implant Technol Res Lab, D-18057 Rostock, Germany
[2] Univ Rostock, Chair Tech Dynam, Fac Mech Engn & Marine Technol, D-18059 Rostock, Germany
[3] DOT GmbH, D-18059 Rostock, Germany
关键词
Total hip replacement; Relative motion; Joint angles; Load; Force; Wear; Hip simulator; IN-VITRO; FEMORAL-HEAD; PARTICLES; METAL; IMPLANTS; MICROSEPARATION; PROSTHESES; GAIT; REPLACEMENTS; KINEMATICS;
D O I
10.1016/j.medengphy.2012.07.014
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
At present, wear investigations of total hip replacements are performed in accordance with the ISO standard 14242, which is based on simplified kinematic and force data of the gait cycle. The aim of this analytical study was to generate parameter sets of daily life activities in order to replicate more realistic joint load situations in wear testing. Hence, published in vivo motion and force data of daily life activities were evaluated and adjusted using analytical techniques. The created kinematically and dynamically consistent parameter sets comprised time trajectories of three Cardan angles to describe the motion of the femur with respect to the pelvis and time trajectories of three force components, representing the hip joint contact force. The parameter sets include the activities of walking, knee bending, stair climbing and a combined load case of sitting down and standing up. Additionally, a motion sequence following the frequency of daily life activities was presented. Differences of the evaluated angular motions and joint contact forces in comparison to the ISO standard 14242-1 were pointed out. The results of this study offer the possibility to extend the kinematics and dynamics of the ISO standard test protocol and to support the loading conditions of hip wear simulators with a comprehensive set of motions and loads close to reality. (c) 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 42 条
[1]
Alumina-on-alumina hip implants A WEAR STUDY OF RETRIEVED COMPONENTS [J].
Affatato, S. ;
Traina, F. ;
De Fine, M. ;
Carmignato, S. ;
Toni, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (01) :37-42
[2]
Tribology and total hip joint replacement: Current concepts in mechanical simulation [J].
Affatato, S. ;
Spinelli, A. ;
Zavalloni, M. ;
Mazzega-Fabbro, C. ;
Viceconti, A. .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (10) :1305-1317
[3]
[Anonymous], 2012, 1424212012 ISO
[4]
Asseman F., 2008, MED ENG PHYS, V30, P1305
[5]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[6]
Bergmann G., 2001, HIP98 LOADING HIP JO
[7]
Metal-on-metal hip simulator study of increased wear particle surface area due to 'severe' patient activity [J].
Bowsher, JG ;
Hussain, A ;
Williams, PA ;
Shelton, JC .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :279-287
[8]
Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses [J].
Brown, C ;
Fisher, J ;
Ingham, E .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :355-369
[9]
Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation [J].
Brown, Christopher ;
Williams, Sophie ;
Tipper, Joanne L. ;
Fisher, John ;
Ingham, Eileen .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2007, 18 (05) :819-827
[10]
Calonius O., 2003, Acta Polytechnica, Czech Technical University in Prague, V43, P43