A copper-selective electrode based on bis(acetylacetone)propylenediimine

被引:61
作者
Gupta, VK [1 ]
Goyal, RN
Bachheti, N
Singh, LP
Agarwal, S
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[2] Cent Bldg Res Inst, Roorkee 247667, Uttar Pradesh, India
关键词
ion-selective electrodes; copper; bis(acetylacetone)propylenediimine;
D O I
10.1016/j.talanta.2005.06.050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potentiometric response characteristics of Cu2+-selective electrodes based on bis(acetylacetone)propylenediimine (I) combined with anion localizing agent (sodium tetraphenyl borate (NaTPB)) and solvent mediators (dibutyl butyl phosphonate (DBBP), tri-n-butyl phosphate (TBP) and chloronaphthalene (CN)) were investigated. The best results for Cu2+ sensing was obtained for the electrode membrane containing PVC, I, DBBP and NaTPB in composition 5:100:200:6 (I:PVC:DBBP:NaTPB) (w/w; mg), where the electrode had a Nernstian response (30.0 mV/decade) to Cu2+ within the concentration range 1.0 x 10(-5) to 1.0 x 10(-1) M and detection limit of 0.5 ppm. The operational pH range of the electrode was 3.3-7.0. Selectivity characteristic of the proposed electrode was also assessed by calculating K-A.B(Pot) using fixed interference method matched potential method. The sensor has been successfully used in the potentiometric titration of copper ions with EDTA. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:193 / 197
页数:5
相关论文
共 20 条
[1]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[2]   PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :541-544
[3]   Response of the jalpaite membrane copper(II) ion-selective electrode in marine waters [J].
DeMarco, R ;
Mackey, DJ ;
Zirino, A .
ELECTROANALYSIS, 1997, 9 (04) :330-334
[4]   DETERMINATION AND APPLICATION OF ION-SELECTIVE ELECTRODE MODEL PARAMETERS USING FLOW-INJECTION AND SIMPLEX OPTIMIZATION [J].
DEVITERI, FJS ;
DIAMOND, D .
ANALYST, 1994, 119 (05) :749-758
[5]   Copper-selective PVC membrane electrodes based on salens as carriers [J].
Fakhari, AR ;
Raji, TA ;
Naeimi, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 104 (02) :317-323
[6]   DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BY A MATCHED-POTENTIAL METHOD [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :279-282
[7]   Copper(II) ion-selective electrodes based on dithiosalicylic and thiosalicylic acids [J].
Gismera, MJ ;
Procopio, JR ;
Sevilla, MT ;
Hernández, L .
ELECTROANALYSIS, 2003, 15 (02) :126-132
[8]  
Guilbault G. G., 1978, IUPAC INF B, V1, P69
[9]   Preparation of ethambutol-copper(II) complex and fabrication of PVC based membrane potentiometric sensor for copper [J].
Gupta, VK ;
Prasad, R ;
Kumar, A .
TALANTA, 2003, 60 (01) :149-160
[10]  
JAIN AK, 1994, INDIAN J CHEM A, V33, P272