A electrochemiluminescence aptasensor for detection of thrombin incorporating the capture aptamer labeled with gold nanoparticles immobilized onto the thio-silanized ITO electrode

被引:85
作者
Fang, Lanyun [1 ,2 ,3 ]
Lv, Zhaozi [1 ]
Wei, Hui [1 ,2 ]
Wang, Erkang [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
[3] Ningbo Municipal Ctr Dis Control & Prevent, Ningbo 315010, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemiluminescence (ECL); Aptasensor; Thrombin; Gold nanoparticle;
D O I
10.1016/j.aca.2008.08.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrochemiluminescence (ECL) aptasensor was proposed for sensitive and cost-effective detection of the target thrombin adopted an aptamer-based sandwich format. To detect thrombin, capture aptamers; labeled with gold nanoparticles (AuNPs) were first immobilized onto the thio-silanized ITO electrode surface through strong Au-S bonds. After catching the target thrombin, signal aptamers; tagged with ECL labels were attached to the assembled electrode surface. As a result, an AuNPs-capture-aptamer/thrombin/ECL-tagged signal-aptamer sandwich type was formed. Treating the resulting electrode surface with tri-n-propylamine (TPA) and applying a swept potential to the electrode, ECL response was generated which realized the detection of target protein. Spectroscopy and electrochemical impedance techniques were used to characterize and confirm the fabrication of the ECL aptasensor. AuNPs amplification and smart sensor fabrication art were implemented for the sensitive and cost-effective detection purpose. Signal-to-dose curve excellently followed a sandwich format equation and could be used to quantify the protein, and the detection limit was estimated to be 10 nM. Other forms of thrombin such as beta- and gamma-thrombins had negligible response, which indicated a high specificity of alpha-thrombin detection. The aptasensor opened up new fields of aptamer applications in ECL domain, a highly sensitive technique, and had a promising perspective to be applied in microarray analysis. (C) 2008 Published by Elsevier B.V
引用
收藏
页码:80 / 86
页数:7
相关论文
共 52 条
[1]   Regenerable biosensor platform: A total internal reflection fluorescence cell with electrochemical control [J].
Asanov, AN ;
Wilson, WW ;
Odham, PB .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1156-1163
[2]  
Baker BR, 2006, J AM CHEM SOC, V128, P3138, DOI 10.1021/ja056957p
[3]   Aptasensor development: Elucidation of critical parameters for optimal aptamer performance [J].
Baldrich, E ;
Restrepo, A ;
O'Sullivan, CK .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :7053-7063
[4]   Following aptamer-thrombin binding by force measurements [J].
Basnar, Bernhard ;
Elnathan, Roey ;
Willner, Itamar .
ANALYTICAL CHEMISTRY, 2006, 78 (11) :3638-3642
[5]  
BLACKBURN GF, 1991, CLIN CHEM, V37, P1534
[6]   Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads [J].
Centi, Sonia ;
Tombelli, Sara ;
Minunni, Maria ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1466-1473
[7]   Staining of cell surface human CD4 with 2′-F-pyrimidine-containing RNA aptamers for flow cytometry [J].
Davis, KA ;
Lin, Y ;
Abrams, B ;
Jayasena, SD .
NUCLEIC ACIDS RESEARCH, 1998, 26 (17) :3915-3924
[8]   Modified-RNA aptamer-based sensor for competitive impedimetric assay of neomycin B [J].
de-los-Santos-Alvarez, Noemi ;
Lobo-Castanon, Maria Jesus ;
Miranda-Ordieres, Arturo J. ;
Tunon-Blanco, Paulino .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (13) :3808-+
[9]   Recent applications of electrogenerated chemiluminescence in chemical analysis [J].
Fähnrich, KA ;
Pravda, M ;
Guilbault, GG .
TALANTA, 2001, 54 (04) :531-559
[10]   Quantitative electrochemiluminescence detection of proteins:: Avidin-based sensor and tris(2,2′-bipyridine) ruthenium(II) label [J].
Fang, Lanyun ;
Lue, Zhaozi ;
Wei, Hui ;
Wang, Erkang .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) :1645-1651