A electrochemiluminescence aptasensor for detection of thrombin incorporating the capture aptamer labeled with gold nanoparticles immobilized onto the thio-silanized ITO electrode

被引:85
作者
Fang, Lanyun [1 ,2 ,3 ]
Lv, Zhaozi [1 ]
Wei, Hui [1 ,2 ]
Wang, Erkang [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
[3] Ningbo Municipal Ctr Dis Control & Prevent, Ningbo 315010, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemiluminescence (ECL); Aptasensor; Thrombin; Gold nanoparticle;
D O I
10.1016/j.aca.2008.08.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrochemiluminescence (ECL) aptasensor was proposed for sensitive and cost-effective detection of the target thrombin adopted an aptamer-based sandwich format. To detect thrombin, capture aptamers; labeled with gold nanoparticles (AuNPs) were first immobilized onto the thio-silanized ITO electrode surface through strong Au-S bonds. After catching the target thrombin, signal aptamers; tagged with ECL labels were attached to the assembled electrode surface. As a result, an AuNPs-capture-aptamer/thrombin/ECL-tagged signal-aptamer sandwich type was formed. Treating the resulting electrode surface with tri-n-propylamine (TPA) and applying a swept potential to the electrode, ECL response was generated which realized the detection of target protein. Spectroscopy and electrochemical impedance techniques were used to characterize and confirm the fabrication of the ECL aptasensor. AuNPs amplification and smart sensor fabrication art were implemented for the sensitive and cost-effective detection purpose. Signal-to-dose curve excellently followed a sandwich format equation and could be used to quantify the protein, and the detection limit was estimated to be 10 nM. Other forms of thrombin such as beta- and gamma-thrombins had negligible response, which indicated a high specificity of alpha-thrombin detection. The aptasensor opened up new fields of aptamer applications in ECL domain, a highly sensitive technique, and had a promising perspective to be applied in microarray analysis. (C) 2008 Published by Elsevier B.V
引用
收藏
页码:80 / 86
页数:7
相关论文
共 52 条
[21]   Enhanced electrochemical detection of DNA hybridization based on electrode-surface modification [J].
Lee, TMH ;
Li, LL ;
Hsing, IM .
LANGMUIR, 2003, 19 (10) :4338-4343
[22]   Electrochemical impedance spectroscopy for study of aptamer-thrombin interfacial interactions [J].
Li, Xiaoxia ;
Shen, Lihua ;
Zhang, Dongdong ;
Qi, Honglan ;
Gao, Qiang ;
Ma, Fen ;
Zhang, Chengxiao .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) :1624-1630
[23]   Electrogenerated chemiluminescence aptamer-based method for the determination of thrombin incorporating quenching of tris(2,2′-bipyridine)ruthenium by ferrocene [J].
Li, Yan ;
Qi, Honglan ;
Peng, Yage ;
Gao, Qiang ;
Zhang, Chengxiao .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (09) :1322-1325
[24]   Electrogenerated chemiluminescence aptamer-based biosensor for the determination of cocaine [J].
Li, Yan ;
Qi, Honglan ;
Peng, Yage ;
Yang, Jia ;
Zhang, Chengxiao .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (10) :2571-2575
[25]   Fabrication and characterization of RNA aptamer microarrays for the study of protein-aptamer interactions with SPR imaging [J].
Li, Yuan ;
Lee, Hye Jin ;
Corn, Robert M. .
NUCLEIC ACIDS RESEARCH, 2006, 34 (22) :6416-6424
[26]   An aptamer-based quartz crystal protein biosensor [J].
Liss, M ;
Petersen, B ;
Wolf, H ;
Prohaska, E .
ANALYTICAL CHEMISTRY, 2002, 74 (17) :4488-4495
[27]   Aptamer-based biosensor arrays for detection and quantification of biological macromolecules [J].
McCauley, TG ;
Hamaguchi, N ;
Stanton, M .
ANALYTICAL BIOCHEMISTRY, 2003, 319 (02) :244-250
[28]   Electrogenerated chemiluminescence.: 77.: DNA hybridization detection at high amplification with [Ru(bpy)3]2+-containing microspheres [J].
Miao, WJ ;
Bard, AJ .
ANALYTICAL CHEMISTRY, 2004, 76 (18) :5379-5386
[29]   Electrogenerated chemluminescence.: 72.: Determination of immobilized DNA and C-reactive protein on Au(111) electrodes using Tris(2,2′-bipyridyl)ruthenium(II) labels [J].
Miao, WJ ;
Bard, AJ .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5825-5834
[30]   Circular dichroism spectra demonstrate formation of the thrombin-binding DNA aptamer G-quadruplex under stabilizing-cation-deficient conditions [J].
Nagatoishi, Satoru ;
Tanaka, Yoshikazu ;
Tsumoto, Kouhei .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2007, 352 (03) :812-817