Constrained segment shapes in direct-aperture optimization for step-and-shoot IMRT

被引:36
作者
Bedford, JL
Webb, S
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Fdn Trust, Sutton SM2 5PT, Surrey, England
基金
英国医学研究理事会;
关键词
radiotherapy; IMRT; segmental; step-and-shoot; optimization; treatment plan;
D O I
10.1118/1.2163832
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Previous studies have shown that, by optimizing segment shapes and weights directly, without explicitly optimizing fluence profiles, effective IMRT plans can be generated with fewer segments. This study proposes a method of direct-aperture optimization with aperture shape constraints, which is designed to provide segmental IMRT plans using a minimum of simple, regular segments. The method uses a cubic function to create smoothly curving multileaf collimator shapes. Constraints on segment dimension and equivalent square are applied, and each segment can be constrained to lie within the previous one, for easy generation of fluence profiles with a single maximum. To simply optimize the segment shapes and reject any shapes which violate the constraints is too inefficient, so an innovative method of feedback optimization is used to ensure in advance that viable aperture shapes are generated. The algorithm is demonstrated using a simple cylindrical phantom consisting of a hemi-annular planning target volume and a central cylindrical organ-at-risk. A simple IMRT rectum case is presented, where segments are used to replace a wedge. More complex cases of prostate and seminal vesicles and prostate and pelvic nodes are also shown. The algorithm produces effective plans in each case with three to five segments per beam. For the simple plans, the constraint that each segment should be contained within the previous one adds additional simplicity to the plan, for a small reduction in plan quality. This study confirms that direct-aperture optimization gives efficient solutions to the segmental IMRT inverse problem and provides a method for generating simple apertures. By using such a method, the workload of IMRT verification may be reduced and simplified, as verification of fluence profiles from individual beams may be eliminated. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:944 / 958
页数:15
相关论文
共 33 条
[1]   Clinical implementation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvement [J].
Adams, EJ ;
Convery, DJ ;
Cosgrove, VP ;
McNair, HA ;
Staffurth, JN ;
Vaarkamp, J ;
Nutting, CM ;
Warrington, AP ;
Webb, S ;
Balyckyi, J ;
Dearnaley, DP .
RADIOTHERAPY AND ONCOLOGY, 2004, 70 (01) :1-10
[2]  
ADAMS EJ, 2002, RADIOTHER ONCOL, V64, pS125
[3]  
Bedford James L, 2004, J Appl Clin Med Phys, V5, P1, DOI 10.1120/jacmp.2020.25271
[4]   Elimination of importance factors for clinically accurate selection of beam orientations, beam weights and wedge angles in conformal radiation therapy [J].
Bedford, JL ;
Webb, S .
MEDICAL PHYSICS, 2003, 30 (07) :1788-1804
[5]   Speed versus accuracy in a fast convolution photon dose calculation for conformal radiotherapy [J].
Bedford, JL .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (19) :3475-3484
[6]   Hardware-sensitive optimization for intensity modulated radiotherapy [J].
Cho, PS ;
Marks, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) :429-440
[7]  
Clark C H, 2002, J Appl Clin Med Phys, V3, P273, DOI 10.1120/1.1499095
[8]   Combinational use of conformal and intensity-modulated beams in radiotherapy planning [J].
Coolens, C ;
Webb, S ;
Evans, PM ;
Seco, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (12) :1795-1807
[9]   Segment-based dose optimization using a genetic algorithm [J].
Cotrutz, C ;
Xing, L .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (18) :2987-2998
[10]   Leaf position optimization for step-and-shoot IMRT [J].
De Gersem, W ;
Claus, F ;
De Wagter, C ;
Van Duyse, B ;
De Neve, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (05) :1371-1388