Applications, potentialities and limitations of adsorptive stripping analysis on mercury film electrodes

被引:47
作者
Economou, A [1 ]
Fielden, PR [1 ]
机构
[1] UNIV MANCHESTER,INST SCI & TECHNOL,DEPT INSTRUMENTAT & ANALYT SCI,MANCHESTER M60 1QD,LANCS,ENGLAND
关键词
D O I
10.1016/S0165-9936(97)00032-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article reviews the field of adsorptive stripping analysis (AdSA) on mercury film electrodes (MFEs). Mercury thin films deposited on conductive substrates can be used as electrodes in the reductive mode of AdSA since they retain most of the favourable features of the hanging mercury drop electrode while offering the advantages of solid electrodes at the same time. The practical aspects of the application of MFEs in AdSA are discussed and some applications in the field of inorganic and organic trace analysis are presented.
引用
收藏
页码:286 / 292
页数:7
相关论文
共 32 条
[1]  
ADELOJU SB, 1995, ELECTROANAL, V7, P576
[2]   DETERMINATION OF ULTRA-TRACE CONCENTRATIONS OF TIN BY ADSORPTIVE CATHODIC STRIPPING VOLTAMMETRY ON A GLASSY-CARBON MERCURY FILM ELECTRODE [J].
ADELOJU, SBO ;
PABLO, F .
ANALYTICA CHIMICA ACTA, 1992, 270 (01) :143-152
[3]   ANALYTICAL DETERMINATION OF NICKEL IN THE ENVIRONMENT BY ADSORPTION VOLTAMMETRY USING THE MERCURY FILM ELECTRODE [J].
BRAUN, H ;
METZGER, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 318 (05) :321-326
[4]   ADSORPTIVE STRIPPING VOLTAMMETRY OF COBALT AND NICKEL IN FLOW SYSTEMS AT WALL-JET ELECTRODES [J].
BRETT, CMA ;
BRETT, AMCFO ;
PEREIRA, JLC .
ELECTROANALYSIS, 1991, 3 (07) :683-689
[5]   Application of nafion-coated mercury film electrodes to the microdetermination of formaldehyde by differential-pulse voltammetry [J].
Chan, WH ;
Huang, H .
ANALYST, 1996, 121 (11) :1727-1730
[6]   NOVEL MERCURY-COATED CARBON-FIBER VOLTAMMETRIC DETECTOR FOR USE IN ADSORPTIVE STRIPPING FLOW-ANALYSIS [J].
DELPOZO, JA ;
COSTAGARCIA, A ;
TUNONBLANCO, P .
ANALYTICA CHIMICA ACTA, 1994, 289 (02) :169-176
[7]   PHASE-SELECTIVE ALTERNATING-CURRENT ADSORPTIVE STRIPPING VOLTAMMETRY OF FOLIC-ACID ON A MERCURY THIN-FILM ELECTRODE [J].
DELPOZO, JA ;
GARCIA, AC ;
ORDIERES, AJM ;
BLANCO, PT .
ELECTROANALYSIS, 1992, 4 (01) :87-92
[8]   AUTOMATIC ADSORPTIVE STRIPPING VOLTAMMETRY AT THIN-MERCURY FILM ELECTRODES (TMFE) - THE HIGHLY-REPRODUCIBLE PLATING AND RENEWING OF THIN MERCURY FILMS ON GLASSY-CARBON FOR THE DETERMINATION OF NICKEL [J].
DIEDERICH, HJ ;
MEYER, S ;
SCHOLZ, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (8-9) :670-675
[9]   ONLINE DETERMINATION OF CHROMIUM BY ADSORPTIVE CATHODIC STRIPPING VOLTAMMETRY [J].
DOBNEY, AM ;
GREENWAY, GM .
ANALYST, 1994, 119 (02) :293-297
[10]   SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRY ON MERCURY FILM ELECTRODES [J].
ECONOMOU, A ;
FIELDEN, PR .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :27-34