Transduction platforms and biointerfacial design of biosensors for 'real-time' biomolecular interaction analysis

被引:23
作者
Quinn, JG [1 ]
O'Kennedy, R [1 ]
机构
[1] Dublin City Univ, Sch Biotechnol, Dublin 9, Ireland
关键词
surface plasmon resonance; evanescent field; 'real-time'; immobilisation; biosensor;
D O I
10.1080/00032719908542911
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The field of biomolecular interaction analysis has been revolutionised over the past decade with the development of biosensors that enable 'real-time' monitoring. Characteristically, these biosensing technologies combine mass sensitive transducers, biointerfacial chemistry and the specificity of a wide range of affinity ligands. Considerable development of these elements has occurred over the past few years and promises to create a new generation of portable biosensors. The majority of transducers for 'real-time' biomolecular interaction analysis are generic evanescent wave-based mass sensors or direct mass sensors. The construction of a suitable biointerface is a key component in biosensor design and has a critical influence on the biosensor's performance. Recent developments in these areas are presented with particular emphasis on commercially available technology.
引用
收藏
页码:1475 / 1517
页数:43
相关论文
共 140 条
[11]  
*BIACORE AB, 1999, BIA J, V5, P17
[12]  
*BIACORE AB, 1995, 106
[13]   REAL-TIME ANALYSIS OF COMPETITIVE-BINDING USING GRATING COUPLER IMMUNOSENSORS FOR PESTICIDE DETECTION [J].
BIER, FF ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (02) :125-130
[14]  
BJORCK L, 1984, J IMMUNOL, V133, P969
[15]   LACTOSE REPRESSOR-OPERATOR DNA INTERACTIONS - KINETIC-ANALYSIS BY A SURFACE-PLASMON RESONANCE BIOSENSOR [J].
BONDESON, K ;
FROSTELLKARLSSON, A ;
FAGERSTAM, L ;
MAGNUSSON, G .
ANALYTICAL BIOCHEMISTRY, 1993, 214 (01) :245-251
[16]   Studies of protein interactions by biosensor technology: An alternative approach to the analysis of sensorgrams deviating from pseudo-first-order kinetic behavior [J].
Bowles, MR ;
Hall, DR ;
Pond, SM ;
Winzor, DJ .
ANALYTICAL BIOCHEMISTRY, 1997, 244 (01) :133-143
[17]   Recent developments in optical transducers for chemical or biochemical applications [J].
Brecht, A ;
Gauglitz, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 38 (1-3) :1-7
[18]   OPTICAL PROBES AND TRANSDUCERS [J].
BRECHT, A ;
GAUGLITZ, G .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (9-10) :923-936
[19]   THE RESONANT MIRROR - A NOVEL OPTICAL SENSOR FOR DIRECT SENSING OF BIOMOLECULAR INTERACTIONS .2. APPLICATIONS [J].
BUCKLE, PE ;
DAVIES, RJ ;
KINNING, T ;
YEUNG, D ;
EDWARDS, PR ;
POLLARDKNIGHT, D ;
LOWE, CR .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) :355-363
[20]   Quartz crystal microbalance study of DNA immobilization and hybridization for nucleic acid sensor development [J].
Caruso, F ;
Rodda, E ;
Furlong, DF ;
Niikura, K ;
Okahata, Y .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2043-2049