Development of an immunosensor for human ferritin, a nonspecific tumor marker, based on surface plasmon resonance

被引:75
作者
Chou, SF [1 ]
Hsu, WL
Hwang, JM
Chen, CY
机构
[1] Chia Nan Univ Pharm & Sci, Dept Biotechnol, Tainan, Taiwan
[2] Natl Taiwan Univ, Dept Agr Chem, Taipei, Taiwan
[3] Natl Def Med Ctr, Tri Serv Gen Hosp, Dept Radiat Oncol, Taipei, Taiwan
关键词
human ferritin; immunosensor; surface plasmon resonance (SPR); self-assembled monolayer (SAM);
D O I
10.1016/j.bios.2003.09.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A direct human ferritin immunosensor was developed using anti-human ferritin monoclonal antibodies (MAbs) immobilized on the gold surface of a self-assembled surface plasmon resonance (SPR) apparatus. A kind of self-assembled monolayer (SAM) prepared by cystamine-glutaraldehyde method was applied to immobilize the MAbs. The reusability of the sensor chip adopting the SAM was found to be better than the other immobilization methods including adsorption, protein A, concanavalin A method. Ten cycles of measurements could be performed on the same chip regenerated with a 0.1 M HCl Solution. A linear relationship existed between the angle shifts (millidegrees) and the log values of ferritin concentrations in the range from 0.2 to 200 ng/ml in buffer and human serum. When used for 15 days, the angle shifts were all >95% of those on the response at the first day. A 10M NjOH Solution was used for clearing nonspecific binding in human serum. Correlation coefficient was 0.991 between this SPR method and chemiluminescent immunoassay for determination of ferritin in clinical human serum samples. The SPR sensor offers advantages of simplicity of immobilization, high sensitivity, high specificity, low sample requirement, high reusability, no label and no pretreatment etc. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:999 / 1005
页数:7
相关论文
共 30 条
  • [11] A GOAT-ANTI-HUMAN IGG MODIFIED PIEZOIMMUNOSENSOR FOR STAPHYLOCOCCUS-AUREUS DETECTION
    LE, D
    HE, FJ
    JIANG, TJ
    NIE, LH
    YAO, SZ
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 1995, 23 (02) : 229 - 234
  • [12] EXTREMELY ELEVATED SERUM FERRITIN LEVELS IN A UNIVERSITY HOSPITAL - ASSOCIATED DISEASES AND CLINICAL-SIGNIFICANCE
    LEE, MH
    MEANS, RT
    [J]. AMERICAN JOURNAL OF MEDICINE, 1995, 98 (06) : 566 - 571
  • [13] LEVI S, 1988, J BIOL CHEM, V263, P18086
  • [14] MATHEWSON PR, 1992, BIOSENSORS DESIGN AP
  • [15] Morgan CL, 1996, CLIN CHEM, V42, P193
  • [16] FBL blood test as a predictive marker of breast cancer in high risk women
    Moroz, C
    Chetrit, A
    Kahn, M
    Modan, B
    [J]. MEDICAL ONCOLOGY, 1997, 14 (01) : 39 - 42
  • [17] Detection of the red tide-causing plankton Chattonella marina using a piezoelectric immunosensor
    Nakanishi, K
    Karube, I
    Hiroshi, S
    Uchida, A
    Ishida, Y
    [J]. ANALYTICA CHIMICA ACTA, 1996, 325 (1-2) : 73 - 80
  • [18] Ola SO, 1995, TROP GEOGR MED, V47, P302
  • [19] Olive A, 1996, AM J MED, V101, P120
  • [20] CLINICAL-SIGNIFICANCE OF SERUM FERRITIN IN PATIENTS WITH RENAL-CELL CARCINOMA
    OZEN, H
    UYGUR, C
    SAHIN, A
    TEKGUL, S
    ERGEN, A
    REMZI, D
    [J]. UROLOGY, 1995, 46 (04) : 494 - 498