Accuracy of technetium-99m sestamibi scintimammography and X-ray mammography in premenopausal women with suspected breast cancer

被引:17
作者
Lumachi, F
Ferretti, G
Povolato, M
Marzola, MC
Zucchetta, P
Geatti, O
Brandes, AA
Bui, F
机构
[1] Univ Padua, Sch Med, Dept Surg & Gastroenterol Sci, Endocrine Surg Unit, I-35128 Padua, Italy
[2] Univ Padua, Sch Med, Dept Diagnost Med Sci, Nucl Med Serv, I-35128 Padua, Italy
[3] Azienda Osped, Div Med Oncol, I-35128 Padua, Italy
[4] Osped Riuniti, Nucl Med Serv, I-34100 Trieste, Italy
关键词
scintimammography; mammography; breast cancer; premenopausal women; diagnosis;
D O I
10.1007/s00259-001-0665-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate the usefulness of technetium-99m sestamibi scintimammography (SSM) and combined use of SSM and X-ray mammography (MG) in premenopausal patients with small (less than or equal to2 cm) suspicious breast lesions. Eighty-seven premenopausal women (median age 47 years, range 32-52) with breast lesions ranging from 4 to 20 mm in greatest diameter (median 12 mm) and detected by MG. underwent SSM prior to open breast biopsy. A planar camera and single-photon emission tomography (SPET) technique were used in 23 (26.4%) and 64 (73.6%) patients, respectively. At histological examination, 72 (82.8%) breast cancers (pT1a=3, pT1b=27, pT1c=42) and 15 (17.2%) benign masses were found. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of MG and SSM were 80.6% vs 80.6%, 60.0% vs 93.3% (P<0.05). 90.6% vs 98.3%, 39.1% vs 50.0% and 77.0% vs 82.8%. respectively. MG + SSM together had a sensitivity of 94.4% (P<0.05 vs SSM alone) and an accuracy of 82.8% for the detection of breast cancer. Tumours undetected by both MG and SSM were significantly (P<0.05) smaller than those correctly diagnosed. Patients with false-negative MG were younger (P<0.05) than those with tumours correctly detected, while SSM sensitivity was independent (P=NS) of age. In conclusion, in premenopausal patients with small breast lesions, the sensitivity of SSM and MG is similar (P=NS), whereas the specificity of SSM is significantly higher (P<0.05) than that of MG. Furthermore, the combination of MG and SSM offers significantly improved sensitivity and accuracy in comparison with the individual techniques, suggesting a complementary role of SSM in the detection of breast cancer in younger patients.
引用
收藏
页码:1776 / 1780
页数:5
相关论文
共 31 条
[21]  
Palmedo H, 1997, EUR J NUCL MED, V24, P1138
[22]   Scintimammography with technetium-99m methoxyisobutylisonitrile: results of a prospective European multicentre trial [J].
Palmedo, H ;
Biersack, HJ ;
Lastoria, S ;
Maublant, J ;
Prats, E ;
Stegner, HE ;
Bourgeois, P ;
Hustinx, R ;
Hilson, AJW ;
Bischof-Delaloye, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (04) :375-385
[23]   Scintimammographic findings of in situ ductal breast carcinoma in a double-phase study with Tc-99m(V) DMSA and Tc-99m MIBI value of Tc-99m(V) DMSA [J].
Papantoniou, V ;
Sotiropoulou, M ;
Stipsaneli, E ;
Louvrou, A ;
Feda, H ;
Christodoulidou, J ;
Pampouras, G ;
Zerva, C ;
Keramopoulos, A ;
Michalas, S .
CLINICAL NUCLEAR MEDICINE, 2000, 25 (06) :434-439
[24]  
Prats E, 1999, J NUCL MED, V40, P296
[25]  
Scopinaro F, 1997, ANTICANCER RES, V17, P1631
[26]  
Sun SS, 2000, ANTICANCER RES, V20, P2133
[27]  
TAILLEFER R, 1995, J NUCL MED, V36, P1758
[28]   Role of magnetic resonance imaging and magnetic resonance imaging-guided surgery in the evaluation of patients with early-stage breast cancer for breast conservation treatment [J].
Tan, JE ;
Orel, SG ;
Schnall, MD ;
Schultz, DJ ;
Solin, LJ .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 1999, 22 (04) :414-418
[29]   99Tcm-MIBI scintimammography in 300 consecutive patients:: Factors that may affect accuracy [J].
Tofani, A ;
Sciuto, R ;
Semprebene, A ;
Festa, A ;
Pasqualoni, R ;
Giunta, S ;
Mottolese, M ;
Benevolo, M ;
Botti, C ;
Maini, CL .
NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (12) :1113-1121
[30]   Optimization of X-ray mammography and technetium-99m methoxyisobutylisonitrile scintimammography in the diagnosis of non-palpable breast lesions [J].
Uriarte, I ;
Carril, JM ;
Quirce, R ;
Gutierrez-Mendiguchia, C ;
Blanco, I ;
Banzo, I ;
Vega, A ;
Hernández, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (05) :491-496