High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy

被引:679
作者
Chen, Shaoxia [1 ]
McMullan, Greg [1 ]
Faruqi, Abdul R. [1 ]
Murshudov, Garib N. [1 ]
Short, Judith M. [1 ]
Scheres, Sjors H. W. [1 ]
Henderson, Richard [1 ]
机构
[1] MRC Lab Mol Biol, Cambridge CB2 0QH, England
基金
英国医学研究理事会;
关键词
Single particle; Electron cryomicroscopy; Validation; Resolution; Overfitting; Beta-galactosidase; CRYO-EM STRUCTURE; 3-DIMENSIONAL RECONSTRUCTION; ATOMIC MODEL; ANGSTROM RESOLUTION; CRYSTAL-STRUCTURES; ESCHERICHIA-COLI; MICROSCOPY; REFINEMENT; IMAGES; VISUALIZATION;
D O I
10.1016/j.ultramic.2013.06.004
中图分类号
TH742 [显微镜];
学科分类号
摘要
Three-dimensional (3D) structure determination by single particle electron cryomicroscopy (cryoEM) involves the calculation of an initial 3D model, followed by extensive iterative improvement of the orientation determination of the individual particle images and the resulting 3D map. Because there is much more noise than signal at high resolution in the images, this creates the possibility of noise reinforcement in the 3D map, which can give a false impression of the resolution attained. The balance between signal and noise in the final map at its limiting resolution depends on the image processing procedure and is not easily predicted. There is a growing awareness in the cryoEM community of how to avoid such over-fitting and over-estimation of resolution. Equally, there has been a reluctance to use the two principal methods of avoidance because they give lower resolution estimates, which some people believe are too pessimistic. Here we describe a simple test that is compatible with any image processing protocol. The test allows measurement of the amount of signal and the amount of noise from overfitting that is present in the final 3D map. We have applied the method to two different sets of cryoEM images of the enzyme beta-galactosidase using several image processing packages. Our procedure involves substituting the Fourier components of the initial particle image stack beyond a chosen resolution by either the Fourier components from an adjacent area of background, or by simple randomisation of the phases of the particle structure factors. This substituted noise thus has the same spectral power distribution as the original data. Comparison of the Fourier Shell Correlation (FSC) plots from the 3D map obtained using the experimental data with that from the same data with high-resolution noise (HR-noise) substituted allows an unambiguous measurement of the amount of overfitting and an accompanying resolution assessment. A simple formula can be used to calculate an unbiased FSC from the two curves, even when a substantial amount of overfitting is present. The approach is software independent. The user is therefore completely free to use any established method or novel combination of methods, provided the HR-noise test is carried out in parallel. Applying this procedure to cryoEM images of beta-galactosidase shows how overfitting varies greatly depending on the procedure, but in the best case shows no overfitting and a resolution of similar to 6 angstrom. (382 words) (C) 2013 The Authors. Published by Elsevier B. V. All rights reserved.
引用
收藏
页码:24 / 35
页数:12
相关论文
共 58 条
[1]   FREE R-VALUE - A NOVEL STATISTICAL QUANTITY FOR ASSESSING THE ACCURACY OF CRYSTAL-STRUCTURES [J].
BRUNGER, AT .
NATURE, 1992, 355 (6359) :472-475
[2]   4.0-Å resolution cryo-EM structure of the mammalian chaperonin TRiC/CCT reveals its unique subunit arrangement [J].
Cong, Yao ;
Baker, Matthew L. ;
Jakana, Joanita ;
Woolford, David ;
Miller, Erik J. ;
Reissmann, Stefanie ;
Kumar, Ramya N. ;
Redding-Johanson, Alyssa M. ;
Batth, Tanveer S. ;
Mukhopadhyay, Aindrila ;
Ludtke, Steven J. ;
Frydman, Judith ;
Chiu, Wah .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (11) :4967-4972
[3]   Visualization of a 4-helix bundle in the hepatitis B virus capsid by cryo-electron microscopy [J].
Conway, JF ;
Cheng, N ;
Zlotnick, A ;
Wingfield, PT ;
Stahl, SJ ;
Steven, AC .
NATURE, 1997, 386 (6620) :91-94
[4]   MRC image processing programs [J].
Crowther, RA ;
Henderson, R ;
Smith, JM .
JOURNAL OF STRUCTURAL BIOLOGY, 1996, 116 (01) :9-16
[5]   CRYO-ELECTRON MICROSCOPY OF VITRIFIED SPECIMENS [J].
DUBOCHET, J ;
ADRIAN, M ;
CHANG, JJ ;
HOMO, JC ;
LEPAULT, J ;
MCDOWALL, AW ;
SCHULTZ, P .
QUARTERLY REVIEWS OF BIOPHYSICS, 1988, 21 (02) :129-228
[6]   Role of Met-542 as a guide for the conformational changes of Phe-601 that occur during the reaction of β-galactosidase (Escherichia coli) [J].
Dugdale, Megan L. ;
Dymianiw, Dayna L. ;
Minhas, Bhawanjot K. ;
D'Angelo, Igor ;
Huber, Reuben E. .
BIOCHEMISTRY AND CELL BIOLOGY-BIOCHIMIE ET BIOLOGIE CELLULAIRE, 2010, 88 (05) :861-869
[7]   Ab Initio Structure Determination from Electron Microscopic Images of Single Molecules Coexisting in Different Functional States [J].
Elmlund, Dominika ;
Davis, Ralph ;
Elmlund, Hans .
STRUCTURE, 2010, 18 (07) :777-786
[8]   High-resolution single-particle orientation refinement based on spectrally self-adapting common lines [J].
Elmlund, Dominika ;
Elmlund, Hans .
JOURNAL OF STRUCTURAL BIOLOGY, 2009, 167 (01) :83-94
[9]   A new cryo-EM single-particle ab initio reconstruction method visualizes secondary structure elements in an ATP-fueled AAA+ motor [J].
Elmlund, Hans ;
Lundqvist, Joakirn ;
Al-Karadaghi, Salam ;
Hansson, Mats ;
Hebert, Hans ;
Lindahl, Martin .
JOURNAL OF MOLECULAR BIOLOGY, 2008, 375 (04) :934-947
[10]   Electronic detectors for electron microscopy [J].
Faruqi, A. R. ;
McMullan, G. .
QUARTERLY REVIEWS OF BIOPHYSICS, 2011, 44 (03) :357-390