Clinical evaluation of bionime rightest GM310 biosensors with a simplified electrode fabrication for alternative-site blood glucose tests

被引:9
作者
Wu, Ming-Hsun [2 ]
Fang, Mei-Yen [1 ]
Jen, Lin-Ni [1 ]
Hsiao, Hung-Chan [1 ]
Mueller, Andreas [3 ]
Hsu, Cheng-Teng [1 ]
机构
[1] Bionime Corp, Dept Core Tech Res, Taichung, Taiwan
[2] Min Sheng Gen Hosp, Dept Lab Med, Tao Yuan, Taiwan
[3] IMCARMED GmbH, Saalfeld, Germany
关键词
D O I
10.1373/clinchem.2008.106328
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 [基础医学];
摘要
BACKGROUND: Most processes for fabricating biosensors applied to screen-printed carbon electrodes (SPCES) are complex. This study presents a novel one-step process for manufacturing electrodes for injection-molding biosensors. METHODS: During the sensor-fabrication process, barrel-plated gold electrodes were inserted into an injection-molded base. The electrode directly touched the electrical contact of a meter. We analyzed technical measurements for this biosensor, including tests of the measurement range, within-run imprecision, and between-meter imprecision. In clinical trials, experienced technicians tested 3 alternative sites (fingertip, palm, and arm). The results were simultaneously compared with plasma values obtained with the hexokinase method on the Olympus AU640 instrument. Analytical results were evaluated according to International Standards Organization 15197 (ISO 15197: 2003) criteria and by Clarke error grid analysis (EGA), and CVs were calculated to evaluate within-run imprecision. RESULTS: The glucose measurement range was 0.6-33.3 mmol/L (y = 0.96x + 0.07 mmol/L; r(2) = 0.9977). The CVs in the within-run imprecision test were 1.7%-3.5%, and the overall CV was 2.1%, indicating good reproducibility of results. The Student t-tests of mean values from 5 meters revealed statistically insignificant differences (P > 0.05). In clinical trials, the agreement of the Rightest GM310 meter results with those of a laboratory method complied with ISO 15197:2003 criteria. In the EGA, 100% of the values were within the acceptable zones (A + B), and the proportion of values within zone A exceeded 95%. CONCLUSIONS: The Bionime Rightest GM310 meter applied a simplified process for biosensor fabrication and displayed acceptable performance for monitoring glucose concentrations at alternative test sites. (c) 2008 American Association for Clinical Chemistry.
引用
收藏
页码:1689 / 1695
页数:7
相关论文
共 34 条
[1]
[Anonymous], 1996, DIABETES CARE, V19, pS62
[2]
Nocturnal hypoglycemia in children and adolescents with insulin-dependent diabetes mellitus: Prevalence and risk factors [J].
Beregszaszi, M ;
TubianaRufi, N ;
Benali, K ;
Noel, M ;
Bloch, J ;
Czernichow, P .
JOURNAL OF PEDIATRICS, 1997, 131 (01) :27-33
[3]
Evolution of analytical performance in portable glucose meters in the last decade [J].
Böhme, P ;
Floriot, M ;
Sirveaux, MA ;
Durain, D ;
Ziegler, O ;
Drouin, P ;
Guerci, B .
DIABETES CARE, 2003, 26 (04) :1170-1175
[4]
Validation of home blood glucose meters with respect to clinical and analytical approaches [J].
Brunner, GA ;
Ellmerer, M ;
Sendlhofer, G ;
Wutte, A ;
Trajanoski, Z ;
Schaupp, L ;
Quehenberger, F ;
Wach, P ;
Krejs, GJ ;
Pieber, TR .
DIABETES CARE, 1998, 21 (04) :585-590
[5]
ELECTROCATALYSIS OF PROTON-COUPLED ELECTRON-TRANSFER REACTIONS AT GLASSY-CARBON ELECTRODES [J].
CABANISS, GE ;
DIAMANTIS, AA ;
MURPHY, WR ;
LINTON, RW ;
MEYER, TJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1985, 107 (07) :1845-1853
[6]
Technical and clinical evaluation of an electrochemistry glucose meter: experience in a diabetes center [J].
Chen, HS ;
Kuo, BI ;
Hwu, CM ;
Shih, KC ;
Kwok, CF ;
Ho, LT .
DIABETES RESEARCH AND CLINICAL PRACTICE, 1998, 42 (01) :9-15
[7]
A novel, disposable, screen-printed amperometric biosensor for glucose in serum fabricated using a water-based carbon ink [J].
Crouch, E ;
Cowell, DC ;
Hoskins, S ;
Pittson, RW ;
Hart, JP .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (05) :712-718
[8]
Biosensors in clinical chemistry [J].
D'Orazio, P .
CLINICA CHIMICA ACTA, 2003, 334 (1-2) :41-69
[9]
Accuracy of the EasyTouch blood glucose self-monitoring system: a study of 516 cases [J].
Dai, KS ;
Tai, DY ;
Ho, P ;
Chen, CC ;
Peng, WC ;
Chen, ST ;
Hsu, CC ;
Liu, YP ;
Hsieh, HC ;
Yang, CC ;
Tsai, MC ;
Mao, SJT .
CLINICA CHIMICA ACTA, 2004, 349 (1-2) :135-141
[10]
The investigation and management of neonatal hypoglycaemia [J].
Deshpande, S ;
Platt, MW .
SEMINARS IN FETAL & NEONATAL MEDICINE, 2005, 10 (04) :351-361