Seamless multiresolution display of portable wavelet-compressed images

被引:4
作者
Hovanes, ME [1 ]
Deal, JRG [1 ]
Rowberg, AH [1 ]
机构
[1] LizardTech Inc, Seattle, WA 98104 USA
关键词
D O I
10.1007/BF03168772
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Image storage, display, and distribution have been difficult problems in radiology for many years. As improvements in technology have changed the nature of the storage and display media, demand for image portability, faster image acquisition, and flexible image distribution is driving the development of responsive systems. Technology, such as the wavelet-based multiresolution seamless image database (MrSID) portable image format (PIF), is enabling image management solutions that address the shifting "point-of-care." The MrSID PIF employs seamless, multiresolution technology, which allows the viewer to determine the size of the image to be viewed, as well as the position of the viewing area within the image dataset. In addition the MrSID PIF allows control of the compression ratio of decompressed images. This capability offers the advantage of very rapid image recall from storage devices and portability for rapid transmission and distribution using the internet or wide-area networks. For example, in teleradiology, the radiologist or other physician desiring to view images at a remote location has full flexibility in being able to choose a quick display of an overview image, a complete display of a full diagnostic quality image, or both without compromising communication bandwidth. The MrSID algorithm will satisfy Joint Photographic Experts Group (JPEG) 2000 standards, thereby being compatible with future versions of the Digital Imaging and Communications in Medicine (DICOM) standard for image data compression. Copyright (C) 1999 by W.B. Saunders Company.
引用
收藏
页码:109 / 111
页数:3
相关论文
共 7 条
[1]   Multi-resolution storage in a PACS archive [J].
Behlen, FM ;
Hoffmann, KR ;
MacMahon, H ;
Folkner, TR .
PACS DESIGN AND EVALUATION: ENGINEERING AND CLINICAL ISSUES - MEDICAL IMAGING 1997, 1997, 3035 :39-46
[2]  
CHANG PJ, RSNA 98
[3]   Clinical evaluation of irreversible data compression for computed radiography of the chest [J].
Egashira, K ;
Nakata, H ;
Watanabe, H ;
Uchida, K ;
Nakamura, K ;
Ishino, Y ;
Horino, K ;
Yoshikawa, R .
JOURNAL OF DIGITAL IMAGING, 1998, 11 (04) :176-181
[4]   An introduction to wavelet theory and application for the radiological physicist [J].
Harpen, MD .
MEDICAL PHYSICS, 1998, 25 (10) :1985-1993
[5]   Wavelet-based vector quantization for high-fidelity compression and fast transmission of medical images [J].
Mitra, S ;
Yang, SY ;
Kustov, V .
JOURNAL OF DIGITAL IMAGING, 1998, 11 (04) :24-30
[6]   Perceived fidelity of compressed and reconstructed Radiological images: A preliminary exploration of compression, luminance, and viewing distance [J].
Pilgram, TK ;
Slone, RM ;
Muka, E ;
Cox, JR ;
Blaine, GJ .
JOURNAL OF DIGITAL IMAGING, 1998, 11 (04) :168-175
[7]   A review of compression methods for medical images in PACS [J].
Strintzis, MG .
INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 1998, 52 (1-3) :159-165