Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs

被引:205
作者
Kobayashi, T
Xu, XW
MacMahon, H
Metz, CE
Doi, K
机构
[1] Kurt Rossmann Labs. Radiologic I., Department of Radiology, University of Chicago, Chicago, IL 60637
[2] Department of Radiology, Kanazawa University, School of Medicine, Kanazawa
关键词
computers; diagnostic aid; lung; nodule; 60.281; radiography; computer-assisted; radiology reporting system; receiver operating characteristic curve (ROC);
D O I
10.1148/radiology.199.3.8638015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the effect of a computer-aided diagnosis (CAD) scheme on radiologists' performance in the detection of lung nodules, and to examine a new method of receiver operating characteristic (ROC) analysis. MATERIALS AND METHODS: One hundred twenty radiographs (60 normal and 60 abnormal with lung nodules of varying subtlety) were used. Sixteen radiologists (two thoracic, six general, and eight residents) participated in an observer study in which they read both conventional radiographs and digitized radiographs. The radiologists' performance was evaluated with ROC analysis with two different methods (independent testing and sequential testing) and a continuous rating scale. RESULTS: A(z) (area under the best fit binormal ROC curve when it is plotted in the unit square) values obtained from ROC analysis with and without CAD output were 0.940 and 0.894, respectively, in the independent test and 0.948 and 0.906, respectively, in the sequential test. Findings with both methods indicated that the CAD scheme statistically significantly improved diagnostic accuracy, particularly for radiologists with less experience (P < .001). Reading time was not increased when CAD was used. CONCLUSION: The CAD scheme can assist radiologists in the detection of lung nodules on chest radiographs.
引用
收藏
页码:843 / 848
页数:6
相关论文
共 27 条
[21]  
NAIDICH DP, 1984, COMPUT TOMOGR, P171
[22]   INFLUENCE OF STRUCTURED NOISE ON DETECTION OF RADIOLOGIC ABNORMALITIES [J].
REVESZ, G ;
KUNDEL, HL ;
GRABER, MA .
INVESTIGATIVE RADIOLOGY, 1974, 9 (06) :479-486
[23]  
RIES LAG, 1991, 912789 NAT I HLTH PU
[24]   THE USE OF CONTINUOUS AND DISCRETE CONFIDENCE JUDGMENTS IN RECEIVER OPERATING CHARACTERISTIC STUDIES OF DIAGNOSTIC-IMAGING TECHNIQUES [J].
ROCKETTE, HE ;
GUR, D ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :169-172
[25]  
Toriwaki J., 1973, Computer Graphics and Image Processing, V2, P252, DOI [DOI 10.1016/0146-664X(73)90005-1, 10.1016/0146-664X(73)90005-1]
[26]   COMPUTER VISION AND ARTIFICIAL-INTELLIGENCE IN MAMMOGRAPHY [J].
VYBORNY, CJ ;
GIGER, ML .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (03) :699-708
[27]   COMPUTERIZED SCHEME FOR THE DETECTION OF PULMONARY NODULES - A NONLINEAR FILTERING TECHNIQUE [J].
YOSHIMURA, H ;
GIGER, ML ;
DOI, K ;
MACMAHON, H ;
MONTNER, SM .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :124-129