Dosimetric study of the new InterSource125 iodine seed

被引:28
作者
Reniers, B [1 ]
Vynckier, S [1 ]
Scalliet, P [1 ]
机构
[1] Catholic Univ Louvain, Clin Univ St Luc, Serv Radiotherapie Oncol, Brussels, Belgium
关键词
brachytherapy; dosimetry; iodine-125; Monte Carlo simulation;
D O I
10.1118/1.1415072
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The use of low energy photon emitters for brachytherapy applications, as in the treatment of the prostate or of eye tumors, has significantly increased these last few years. New seed models for I-125 have been recently introduced. The aim of this study is to determine the dosimetric parameters as recommended by the AAPM in the TG43 formalism for a new iodine seed design: the InterSource(125) (Furnished by IBt, Seneffe, Belgium). Measurements are made with LiF thermoluminescent dosimeters (size of 1 mm(3)) in solid water phantoms to obtain the dose constant, the radial dose function, and the anisotropy function. The TLDs were calibrated at 6 MV and an energy correction factor of 1.41 has been applied. The same dose parameters are also obtained by Monte Carlo calculations (MCNP4B) in solid water and in liquid water. The radial function was measured at 1, 1.5, 2, 3, 4, 5, 6, and 7 cm and calculated between 0.3 and 7 cm. The anisotropy functions were measured at 2, 3, and 5 cm and calculated between 0.3 and 7 cm. The calculated and the measured TG43 functions for solid water are in excellent agreement. We have then calculated these functions in liquid water to obtain the dosimetric information for clinical applications as per TG43 recommendations. In WT1, the calculated dose rate constant is 0.98 +/- 1% and the measured value is 1.03 +/- 7%. The calculated value for water is 1.02 +/- 1%. In conclusion, the dosimetric functions for the new iodine seed InterSource(125) have been determined. They are quite different from the data of the well-known model 6711 from Amersham due to the absence of silver in the new seed. The characteristics are very similar to those of model 6702. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:2285 / 2288
页数:4
相关论文
共 13 条
[1]
Briesmeister JF, MCNPTM GEN MONTE CAR
[2]
EVERETT CJ, 1973, LA5240MS
[3]
Hubbell J. H., 1975, Journal of Physical and Chemical Reference Data, V4, P471, DOI 10.1063/1.555523
[4]
Experimental measurements of dosimetric parameters on the transverse axis of a new 125I source [J].
Li, ZF ;
Fan, JJ ;
Palta, JR .
MEDICAL PHYSICS, 2000, 27 (06) :1275-1280
[5]
COMPARISON OF RADIATION-DOSIMETRY IN WATER AND IN SOLID PHANTOM MATERIALS FOR I-125 AND PD-103 BRACHYTHERAPY SOURCES - EGS4 MONTE-CARLO STUDY [J].
LUXTON, G .
MEDICAL PHYSICS, 1994, 21 (05) :631-641
[6]
Dosimetric characteristics of the InterSource103 palladium brachytherapy source [J].
Meigooni, AS ;
Sowards, K ;
Soldano, M .
MEDICAL PHYSICS, 2000, 27 (05) :1093-1100
[7]
Dose distribution along the transverse axis of a new 125I source for interstitial brachytherapy [J].
Nath, R ;
Yue, N .
MEDICAL PHYSICS, 2000, 27 (11) :2536-2540
[8]
DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234
[9]
STORM E, 1967, LA3753
[10]
Report on the dosimetry of a new design 125Iodine brachytherapy source [J].
Wallace, RE ;
Fan, JJ .
MEDICAL PHYSICS, 1999, 26 (09) :1925-1931