Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery

被引:69
作者
Grollmuss, Oswin [1 ]
Demontoux, Serge
Capderou, Andre [1 ]
Serraf, Alain
Belli, Emre
机构
[1] Univ Paris 11, INSERM 999, Ctr Chirurg Marie Lannelongue, Dept Pediat Cardiac Intens Care, F-92350 Le Plessis Robinson, France
关键词
Stroke volume; Cardiac output; Electrical velocimetry; Doppler transthoracic echocardiography; Pediatric cardiac intensive care unit; STROKE VOLUME; DOPPLER; THERMODILUTION; CHILDREN; ECHOCARDIOGRAPHY; MONITOR;
D O I
10.1007/s00134-012-2530-3
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Cardiac output (CO), the product of stroke volume (SV) and heart rate, is essential to guarantee organ perfusion, especially in the intensive care setting. As invasive measurement of CO bears the risk of complications there is a need for non-invasive alternatives. We investigated if electrical velocimetry (EV) and transthoracic Doppler (Doppler-TTE) are interchangeable for the non-invasive measurement of SV and able to reflect the post-surgical SV/CO trend. Comparison of SV measurements by EV and Doppler-TTE was performed in 24 newborns after switch operation ( = 240 measurements). Three subgroups of measurements (=periods) were created according to the patients' status in the course of post-surgical CO recovery. Bland-Altman analysis found acceptable bias and limits of agreement for the interchangeability of the two methods. Mean overall SV was 3.7 ml with a mean overall bias of 0.28 ml (=7.6 %). The mean percentage error of 29 % was acceptable according to the method of Critchley and Critchley. Overall precision expressed by the coefficient of variation (CV) was 6.6 % for SVTTE and 4.4 % for SVEV. SVTTE and SVEV medians in the three periods were significantly different and documented the post-surgical CO trend. EV and Doppler-TTE are interchangeable for estimating SV. EV has the advantages of easy handling and allows continuous measurement.
引用
收藏
页码:1032 / 1039
页数:8
相关论文
共 26 条
[1]
HAEMODYNAMIC CHANGES DURING CRANIOTOMY MONITORED BY A BIOIMPEDANCE PLETHYSMOGRAPHIC NONINVASIVE CARDIAC OUTPUT MONITOR [J].
Ali, Zulfiqar ;
Rao, Umamaheswara ;
Jaganath, A. .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2009, 23 (03) :157-161
[2]
Stroke volume equation for impedance cardiography [J].
Bernstein, DP ;
Lemmens, HJM .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (04) :443-450
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
Time course and prognostic value of plasma B-type natriuretic peptide concentration in neonates undergoing the arterial switch operation [J].
Cannesson, Maxime ;
Bionda, Clara ;
Gostoli, Bruno ;
Raisky, Olivier ;
di Filippo, Sylvie ;
Bompard, Dominique ;
Verdrinne, Catherine ;
Rousson, Robert ;
Ninet, Jean ;
Neidecker, Jean ;
Lehot, Jean-Jacques .
ANESTHESIA AND ANALGESIA, 2007, 104 (05) :1059-1065
[5]
Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature [J].
Chew, MS ;
Poelaert, J .
INTENSIVE CARE MEDICINE, 2003, 29 (11) :1889-1894
[6]
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[7]
Darmon P L, 1996, J Am Soc Echocardiogr, V9, P668, DOI 10.1016/S0894-7317(96)90063-2
[8]
DARMON PL, 1994, ANESTHESIOLOGY, V80, P796, DOI 10.1097/00000542-199404000-00011
[9]
Lack of agreement between thermodilution and fick cardiac output in critically ill patients [J].
Dhingra, VK ;
Fenwick, JC ;
Walley, KR ;
Chittock, DR ;
Ronco, JJ .
CHEST, 2002, 122 (03) :990-997
[10]
Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients [J].
Gonzalez, J ;
Delafosse, C ;
Fartoukh, M ;
Capderou, A ;
Straus, C ;
Zelter, M ;
Derenne, JP ;
Similowski, T .
CRITICAL CARE, 2003, 7 (02) :171-178