Acoustic Radiation Force Impulse Elastography for fibrosis evaluation in patients with chronic hepatitis C: An international multicenter study

被引:174
作者
Sporea, Ioan [1 ]
Bota, Simona [1 ]
Peck-Radosavljevic, Markus [2 ]
Sirli, Roxana [1 ]
Tanaka, Hironori [3 ]
Iijima, Hiroko [3 ]
Badea, Radu [4 ]
Lupsor, Monica [4 ]
Fierbinteanu-Braticevici, Carmen [5 ]
Petrisor, Ana [5 ]
Saito, Hidetsugu [6 ]
Ebinuma, Hirotoshi [6 ]
Friedrich-Rust, Mireen [7 ]
Sarrazin, Christoph [7 ]
Takahashi, Hirokazu [8 ]
Ono, Naofumi
Piscaglia, Fabio [9 ,10 ]
Borghi, Alberto [9 ,10 ]
D'Onofrio, Mirko [11 ]
Gallotti, Anna [11 ]
Ferlitsch, Arnulf [2 ]
Popescu, Alina [1 ]
Danila, Mirela [1 ]
机构
[1] Univ Med & Farm Timisoara, Dept Gastroenterol & Hepatol, Timisoara, Romania
[2] Med Univ Vienna, Div Gastroenterol & Hepatol, Vienna, Austria
[3] Hyogo Coll Med, Dept Internal Med, Nishinomiya, Hyogo 6638501, Japan
[4] Univ Med, Med Clin 3, Cluj Napoca, Romania
[5] Univ Hosp, Med Clin 2, Bucharest, Romania
[6] Keio Univ, Sch Med, Dept Internal Med, Tokyo, Japan
[7] Goethe Univ Frankfurt, Dept Internal Med, Frankfurt, Germany
[8] Saga Med Sch, Dept Internal Med, Saga, Japan
[9] Univ Bologna, Dept Clin Med, Div Internal Med, Bologna, Italy
[10] Gen Hosp S Orsola Malpighi, Bologna, Italy
[11] Univ Verona, Univ Hosp GB Rossi, Dept Radiol, I-37100 Verona, Italy
关键词
Acoustic Radiation Force Impulse Elastography (ARFI); Liver stiffness; Liver fibrosis; Chronic hepatitis C; LIVER STIFFNESS MEASUREMENT; TRANSIENT ELASTOGRAPHY; NONINVASIVE ASSESSMENT; VIRAL-HEPATITIS; PERFORMANCE; BIOPSY;
D O I
10.1016/j.ejrad.2012.08.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Aim: The aim of this international multicenter study was to evaluate the reliability of Acoustic Radiation Force Impulse (ARFI) elastography for predicting fibrosis severity, in patients with chronic hepatitis C. Patients and methods: We compared ARFI to liver biopsy (LB) in 914 patients (10 centers, 5 countries) with chronic hepatitis C. In each patient LB (evaluated according to the METAVIR score) and ARFI measurements were performed (median of 5-10 valid measurements, expressed in meters/second - m/s). In 400 from the 914 patients, transient elastography (TE) was also performed (median of 6-10 valid measurements, expressed in kiloPascals - kPa). Results: Valid ARFI measurements were obtained in 911 (99.6%) of 914 cases. On LB 61 cases (6.7%) had F0, 241 (26.4%) had F1, 202 (22.1%) had F2, 187 (20.4%) had F3, and 223 (24.4%) had F4 fibrosis. A highly significant correlation (r = 0.654) was found between ARFI measurements and fibrosis (p < 0.0001). The predictive values of ARFI for various stages of fibrosis were: F >= 1 - cut-off > 1.19 m/s (AUROC = 0.779), F >= 2 - cut-off > 1.33 m/s (AUROC = 0.792), F >= 3 - cut-off > 1.43 m/s (AUROC = 0.829), F = 4 - cut-off > 1.55 m/s (AUROC = 0.842). The correlation with histological fibrosis was not significantly different for TE in comparison with ARFI elastography: r = 0.728 vs. 0.689, p = 0.28. TE was better than ARFI for predicting the presence of liver cirrhosis (p = 0.01) and fibrosis (F >= 1, METAVIR) (p = 0.01). ARFI elastography is a reliable method for predicting fibrosis severity in chronic hepatitis C patients. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:4112 / 4118
页数:7
相关论文
共 20 条
[1]
NONINVASIVE IN VIVO LIVER FIBROSIS EVALUATION USING SUPERSONIC SHEAR IMAGING: A CLINICAL STUDY ON 113 HEPATITIS C VIRUS PATIENTS [J].
Bavu, Eric ;
Gennisson, Jean-Luc ;
Couade, Mathieu ;
Bercoff, Jeremy ;
Mallet, Vincent ;
Fink, Mathias ;
Badel, Anne ;
Vallet-Pichard, Anais ;
Nalpas, Bertrand ;
Tanter, Mickael ;
Pol, Stanislas .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (09) :1361-1373
[2]
Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[3]
BEDOSSA P, 1994, HEPATOLOGY, V20, P15
[4]
Pitfalls of Liver Stiffness Measurement: A 5-Year Prospective Study of 13,369 Examinations [J].
Castera, Laurent ;
Foucher, Juliette ;
Bernard, Pierre-Henri ;
Carvalho, Francoise ;
Allaix, Daniele ;
Merrouche, Wassil ;
Couzigou, Patrice ;
de Ledinghen, Victor .
HEPATOLOGY, 2010, 51 (03) :828-835
[5]
Alanine aminotransferase-based algorithms of liver stiffness measurement by transient elastography (Fibroscan) for liver fibrosis in chronic hepatitis B [J].
Chan, H. L. -Y. ;
Wong, G. L. -H. ;
Choi, P. C. -L. ;
Chan, A. W. -H. ;
Chim, A. M. -L. ;
Yiu, K. K. -L. ;
Chan, F. K. -L. ;
Sung, J. J. -Y. ;
Wong, V. W. -S. .
JOURNAL OF VIRAL HEPATITIS, 2009, 16 (01) :36-44
[6]
Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan® [J].
Ebinuma, Hirotoshi ;
Saito, Hidetsugu ;
Komuta, Mina ;
Ojiro, Keisuke ;
Wakabayashi, Kanji ;
Usui, Shingo ;
Chu, Po-sung ;
Umeda, Rumiko ;
Ishibashi, Yuka ;
Takayama, Tetsurou ;
Kikuchi, Masahiro ;
Nakamoto, Nobuhiro ;
Yamagishi, Yoshiyuki ;
Kanai, Takanori ;
Ohkuma, Kiyoshi ;
Sakamoto, Michiie ;
Hibi, Toshifumi .
JOURNAL OF GASTROENTEROLOGY, 2011, 46 (10) :1238-1248
[7]
Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis [J].
Fierbinteanu-Braticevici, Carmen ;
Andronescu, Dan ;
Usvat, Radu ;
Cretoiu, Dragos ;
Baicus, Cristian ;
Marinoschi, Gabriela .
WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (44) :5525-5532
[8]
Performance of Acoustic Radiation Force Impulse imaging for the staging of liver fibrosis: a pooled meta-analysis [J].
Friedrich-Rust, M. ;
Nierhoff, J. ;
Lupsor, M. ;
Sporea, I. ;
Fierbinteanu-Braticevici, C. ;
Strobel, D. ;
Takahashi, H. ;
Yoneda, M. ;
Suda, T. ;
Zeuzem, S. ;
Herrmann, E. .
JOURNAL OF VIRAL HEPATITIS, 2012, 19 (02) :E212-E219
[9]
Real-time elastography for noninvasive assessment of liver fibrosis in chronic viral hepatitis [J].
Friedrich-Rust, Mireen ;
Ong, Mei-Fang ;
Herrmann, Eva ;
Dries, Volker ;
Samaras, Panagiotis ;
Zeuzem, Stefan ;
Sarrazin, Christoph .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (03) :758-764
[10]
Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography [J].
Friedrich-Rust, Mireen ;
Wunder, Katrin ;
Kriener, Susanne ;
Sotoudeh, Fariba ;
Richter, Swantje ;
Bojunga, Joerg ;
Herrmann, Eva ;
Poynard, Thierry ;
Dietrich, Christoph F. ;
Vermehren, Johannes ;
Zeuzem, Stefan ;
Sarrazin, Christoph .
RADIOLOGY, 2009, 252 (02) :595-604